7 Maintenance and service
Operation manual
17
FTXM60~71A2V1B
Daikin room air conditioner
3P728539-5F – 2024.01
2
1
3 Remove the titanium apatite deodorising filter and the silver
particle filter from all 4 claws.
a Claw
4 Wash the air filters with water or clean them with a vacuum
cleaner.
5 Soak in lukewarm water for about 10 to 15 minutes.
INFORMATION
If the dust does NOT come off easily, wash them with a
neutral detergent diluted in lukewarm water. Dry the air
filters in the shade.
It is recommended to clean the air filters every 2
weeks.
7.6 To clean the titanium apatite
deodorising filter and the silver
particle filter (Ag-ion filter)
INFORMATION
Clean the filter with water every 6 months.
1 Remove the titanium apatite deodorising filter and the silver
allergen removal air purifying filter from all 4 claws.
a Tab
2 Remove the dust from the filter with a vacuum cleaner.
3 Soak the filter for 10 to 15minutes in warm water.
Note: Do NOT remove the filter from the frame.
4 After washing, shake off remaining water and dry the filter in the
shade. Do NOT wring out the filter when removing water.
7.7 To replace the titanium apatite
deodorising filter and the silver
particle filter (Ag-ion filter)
INFORMATION
Replace the filter every 3 years.
1 Remove the filter from the tabs of the filter frame and replace
the filter with a new one.
INFORMATION
Do NOT throw away the filter frame, but use it again.
Dispose of the old filter as non-flammable waste.
To order titanium apatite deodorising filter or silver particle filters,
contact your dealer.
Item Part number
Titanium deodorising filter KAF970A46
Silver particle filter KAF057A41
7.8 To re-install the front panel
1 Attach the front panel. Align the shafts with the slots and push
them all the way in.
2 Close the front panel slowly; press at both sides and at the
centre.