3 | Components
Service manual
182
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
Pins Measured resistance (Ω)
1-2 353.4~406.6
1-3
1-4
1-5
2-3 706.8~813.2
2-4
2-5
3-4
3-5
4-5
Swing raster motor resistance
measurements are correct?
Action
Yes Replace the swing raster motor wiring
harness, see "Repair
procedures"[4182].
No Replace the swing raster motor, see
"Repair procedures"[4182].
3.18.2 Repair procedures
To remove the swing raster motor
Class 20~42 indoor unit
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see "3.14Plate work"[4151].
1 Remove the switch box, see "3.14Plate work"[4151].
2 Put a small drain pan (or container) under the drain hose.
3 Remove the screw from the fixation bracket and pull the drain hose
downwards to remove it from the indoor unit.