ESIE20-11 – 2021.01
3.3.2 Repair procedures
To remove the compressor thermal protector
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see "3.14Plate work"[4151].
Prerequisite: Remove the compressor insulation.
1 Remove the cover of the compressor wire terminals.
aA
A Class 20~35 unit
a Compressor wire terminals cover
aA
A Class 42~71 unit
a Compressor wire terminals cover