Loading...
3 | Components
Service manual
186
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
7 Install the 2 screws to fix the swing raster motor assembly. Do NOT yet tighten
the screws.
d
c
aa b
a Screw (swing raster motor assembly)
b Swing raster motor assembly
c Fan guard
d Swing raster motor rod
8 Connect the swing raster motor rod to the swing raster shaft using soft tools.
9 Tighten the 2 screws to properly fix the swing raster motor assembly.
10 Install the fan guard.
11 Connect the drain hose to the indoor unit.
a
b
a Screw (drain hose)
b Drain hose
12 Install the drain hose fixation bracket. Install and tighten the screw.
13 Install the switch box, see "3.14Plate work"[4151].
Is the problem solved? Action
Yes No further actions required.
No Return to the troubleshooting of the
specific error and continue with the
next procedure.

Table of Contents