Si011281E Outdoor Fan / Fan Motor
Removal Procedure 3
2. Outdoor Fan / Fan Motor
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step Procedure Points
1
Pull out the 2 terminals
(red, white) from the fan
motor capacitor (C2).
Fan motor capacitor (C2)
2
Pull out the 2 terminals
(black: 3_upper, green /
yellow: _upper) from
the terminal board
(X1M).
3
Release the fan motor
lead wire from the hook.
4
Remove the nut and
remove the outdoor fan.
Nut size: M6
Align the mark of the
outdoor fan with the D-cut
section of the motor shaft
when reassembling.
Fan motor lead wire
Fan motor capacitor
Terminal board
(R18989)
Hook
to fan motor:
red
to terminal board
X1M (2_lower): blue
to fan motor:
white
(R19013)
Outdoor fanNut
D-cut
(R18991)
10 mm
(0.39 inch)
(R18954)