Do you have a question about the Daikin REYQ144 and is the answer not in the manual?
Model | REYQ144 |
---|---|
Category | Air Conditioner |
Heating Capacity | 16.0 kW |
Refrigerant | R-410A |
Indoor Unit Compatibility | VRV Indoor Units |
Covers warnings, cautions, and pictograms for safe repair and product handling.
Introduces the service manual for the Year 2006 VRV series Heat Recovery System.
Lists model names for various indoor units, BS units, and outdoor units.
Provides visual representations and names of indoor and outdoor units.
Guides on selecting models based on system name, capacity, and connectable units.
Details specifications for outdoor units, including capacity, dimensions, and components.
Lists detailed specifications for outdoor units like REYQ72MTJU and REYQ96MTJU.
Details specifications for various indoor unit types like cassette and duct.
Provides specifications for BS units, including connection range and capacity.
Explains the refrigerant circuit for REYQ72M/96M and BSVQ36/60M units.
Illustrates the layout of key components like solenoid valves and sensors.
Diagrams showing refrigerant flow during cooling and heating operations.
Defines symbols and lists operation modes for the system.
Explains normal operation, compressor PI control, and fan control.
Details startup, oil return, defrost, and pressure equalizing controls.
Describes protection mechanisms like high pressure, low pressure, and overload protection.
Covers outdoor unit rotation and emergency operation modes.
Explains indoor unit controls like drain pump and thermostat sensor usage.
Outlines the procedure for initial test operation after installation.
Identifies components and switches on the outdoor unit PC board.
Explains how to perform field settings via remote controller or outdoor unit.
Lists troubleshooting steps using the remote controller's inspection/test functions.
Details error codes (A0, A1, E3, F3, etc.) and their troubleshooting steps.
Troubleshooting for central remote controller issues like PC board defects or transmission.
Troubleshooting for schedule timer malfunctions related to transmission or PC board.
Troubleshooting for unified ON/OFF controller issues like operation lamp blinks or display errors.
Provides a step-by-step guide for replacing the INV compressor.
Shows piping diagrams for outdoor, indoor, and BS units.
Provides wiring diagrams for outdoor, field, indoor, and BS units.
Lists electrical and functional parts for outdoor and indoor units with models and symbols.
Lists optional accessories for operation control systems and outdoor units.
Illustrates example connections for heat recovery systems and REFNET components.
Provides resistance/temperature data for various thermistors used in the system.
Shows pressure sensor characteristics and voltage output data.
Details the procedure for replacing inverter power transistors and diode modules.
Discusses characteristics, pressure, and composition of R-410A refrigerant.
Discusses characteristics, pressure, and composition of R-410A refrigerant.
Lists required tools and their compatibility for R-410A refrigerant systems.