Installation and operation manual
VRV IV system air conditioner
English
Installation and operation
manual
VRV IV system air conditioner
REYQ8T7Y1B
REYQ10T7Y1B
REYQ12T7Y1B
REYQ14T7Y1B
REYQ16T7Y1B
REYQ18T7Y1B
REYQ20T7Y1B
REMQ5T7Y1B

Table of Contents

Questions and Answers

  • B
    Brandi BranchSep 23, 2025
    How to fix Daikin REYQ10T7Y1B Air Conditioner ambient temperature sensor malfunction?
    • E
      Ellen WallSep 23, 2025
      If the ambient temperature sensor is malfunctioning on your Daikin Air Conditioner, check the connection on the PCB or actuator.
  • K
    Katie WolfAug 23, 2025
    What to do if my Daikin REYQ10T7Y1B shows a low pressure malfunction?
    • V
      Vanessa CareyAug 25, 2025
      If your Daikin Air Conditioner is showing a low pressure malfunction, first open the stop valves. Then, check the refrigerant level and recharge the unit if needed. Finally, inspect the user interface display and the transmission wiring between the outdoor and indoor units.
  • G
    ggardnerAug 25, 2025
    How to fix a Daikin Air Conditioner indoor unit communication error?
    • A
      Angel MooreAug 26, 2025
      If you experience an indoor unit communication error with your Daikin Air Conditioner, check the user interface connection.
  • C
    Cynthia MartinezAug 27, 2025
    How to troubleshoot a Daikin REYQ10T7Y1B with an activated high pressure switch?
    • B
      Brent WilsonAug 27, 2025
      If the high pressure switch is activated on your Daikin Air Conditioner, check the stop valve situation and inspect for any abnormalities in the field piping or airflow over the air-cooled coil.
  • A
    Alex LindseyAug 27, 2025
    What to do if my Daikin REYQ10T7Y1B has a refrigerant overcharge or stop valve closed?
    • A
      anthony10Aug 27, 2025
      If your Daikin Air Conditioner indicates a refrigerant overcharge or a closed stop valve, check the refrigerant amount and recharge the unit if necessary. Also, ensure that the stop valves are open.
  • T
    Teresa GeorgeSep 17, 2025
    How to troubleshoot Daikin REYQ10T7Y1B electronic expansion valve (lower heat exchanger)?
    • B
      Bryan SandovalSep 17, 2025
      If you are experiencing issues with the electronic expansion valve (lower heat exchanger) (Y3E) on your Daikin Air Conditioner, check the connection on the main PCB (X23A) or the actuator.
  • E
    Elaine MosesSep 14, 2025
    How to troubleshoot Daikin REYQ10T7Y1B Air Conditioner electronic expansion valve (receiver gas)?
    • H
      Haley GreeneSep 14, 2025
      If you are experiencing issues with the electronic expansion valve (receiver gas) (Y4E) on your Daikin Air Conditioner, check the connection on the main PCB (X25A) or the actuator.
  • N
    Nicole HernandezSep 15, 2025
    How to troubleshoot Daikin REYQ10T7Y1B electronic expansion valve (subcool heat exchanger)?
    • J
      Jordan LawrenceSep 15, 2025
      If you are experiencing issues with the electronic expansion valve (subcool heat exchanger) (Y2E) on your Daikin Air Conditioner, check the connection on the main PCB (X22A) or the actuator.
  • C
    Crystal WarnerSep 6, 2025
    What to do if stop valve closed during Daikin REYQ10T7Y1B Air Conditioner system test run?
    • J
      Julie MartinezSep 6, 2025
      If the stop valve is closed or wrong during the system test run of your Daikin Air Conditioner, open the stop valves.
  • M
    martinaprilSep 3, 2025
    How to open a closed liquid stop valve on a Daikin Air Conditioner?
    • J
      Justin McmahonSep 3, 2025
      If the liquid stop valve is closed on your Daikin Air Conditioner, open the liquid stop valve.

Summary

Preparation

Preparing the Installation Site

Details requirements for selecting and preparing the outdoor unit installation site.

Installation Site Requirements of the Outdoor Unit

Specifies the necessary clearances and conditions for installing the outdoor unit.

Additional Installation Site Requirements of the Outdoor Unit in Cold Climates

Additional site considerations for outdoor unit installation in cold weather conditions.

Preparing Refrigerant Piping

Instructions for preparing and selecting refrigerant piping for the system.

Refrigerant Piping Requirements

Specifies the strict requirements for clean and dry refrigerant piping materials.

To Select the Piping Size

Guidance on determining the correct piping sizes based on unit capacity and diagrams.

To Select Refrigerant Branch Kits

Details how to choose refnet joints and headers based on unit capacity.

Multiple Outdoor Units: Possible Layouts

Illustrates allowed piping layouts and connections for multiple outdoor units.

Preparing Electrical Wiring

Covers safety requirements and wiring selection for the system's electrical connections.

Installation

Connect Refrigerant Piping

Covers routing, connecting pipes, using kits, handling holes, protection, and valves.

Route Refrigerant Piping

Instructions on how to route refrigerant piping from front or side connections.

Connect Piping to Outdoor Unit

Details on connecting field piping to the outdoor unit using accessory pipes.

Connect Multi Connection Piping Kit

Instructions for correctly installing multi connection piping kits to avoid unit malfunction.

Multiple Outdoor Units: Knockout Holes

Procedure for handling knockout holes when connecting multiple outdoor units.

Use Stop Valve and Service Port

Instructions on how to properly open and close stop valves and use service ports.

Remove Pinched Pipes

Procedure for safely removing pinched refrigerant pipes, including warnings.

Check Refrigerant Piping

Steps to verify the integrity and condition of the installed refrigerant piping.

Perform Vacuum Drying

Steps to remove moisture and air from the refrigerant piping system.

Charge Refrigerant

Covers precautions, determination of amount, flow charts, and charging methods.

Refrigerant Charging Precautions

Essential safety warnings and important notices before and during refrigerant charging.

Determine Additional Refrigerant Amount

Provides formulas and tables to calculate the required additional refrigerant.

Refrigerant Charging Flow Chart

Visual guide to the refrigerant charging process and available options.

To Charge Refrigerant

Details pre-charging and charging steps, with options for automatic or manual methods.

Automatic Refrigerant Charging

Procedure for the automatic refrigerant charging process, including conditions and limitations.

Manual Refrigerant Charging

Procedure for manually charging the system with refrigerant and subsequent steps.

Refrigerant Charging Error Codes

Lists and explains error codes that may occur during refrigerant charging.

Connecting the Electrical Wiring

Covers field wiring overview, knockout hole guidelines, and transmission wiring connections.

Configuration

Using the Leak Detection Function

Explains the automatic leak detection feature and its prerequisites for activation.

About Automatic Leak Detection

Explains the automatic leak detection feature and its prerequisites for activation.

Commissioning

To Perform a Test Run

Step-by-step guide on how to conduct the system test operation and interpret results.

Correcting After Abnormal Completion of the Test Run

Procedures for rectifying issues identified during the test run and re-testing.

Troubleshooting

Solving Problems Based on Error Codes

How to interpret and resolve issues identified by error codes displayed on the unit.

Error Codes: Overview

A list and explanation of various error codes encountered on the indoor unit user interface.

Operation

Maintenance and Service