EasyManua.ls Logo

Daikin REYQ168TYDN User Manual

Daikin REYQ168TYDN
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
English
Français
Español
INSTALLATION MANUAL
MODEL
REYQ72TTJU
REYQ96TTJU
REYQ120TTJU
REYQ144TTJU
REYQ168TTJU
REYQ192TTJU
REYQ216TTJU
REYQ240TTJU
REYQ264TTJU
REYQ288TTJU
REYQ312TTJU
REYQ336TTJU
REYQ360TTJU
REYQ384TTJU
REYQ408TTJU
REYQ432TTJU
REYQ456TTJU
REYQ72TYDN
REYQ96TYDN
REYQ120TYDN
REYQ144TYDN
REYQ168TYDN
REYQ192TYDN
REYQ216TYDN
REYQ240TYDN
REYQ264TYDN
REYQ288TYDN
REYQ312TYDN
REYQ336TYDN
REYQ360TYDN
REYQ384TYDN
REYQ408TYDN
REYQ432TYDN
REYQ456TYDN
System Air Conditioner
3P362438-3H
00_CV_3P362438-3H.indd 1 1/5/2015 9:24:22 AM

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Daikin REYQ168TYDN and is the answer not in the manual?

Daikin REYQ168TYDN Specifications

General IconGeneral
BrandDaikin
ModelREYQ168TYDN
CategoryAir Conditioner
LanguageEnglish

Summary

Safety Considerations

General Installation Warnings

Covers warnings for qualified personnel, room size, foundation, and environmental factors.

Refrigerant Handling Precautions

Details hazards related to refrigerant leaks, contact, and fire.

Electrical Safety and Wiring Precautions

Highlights risks of electric shock, fire, and proper grounding.

Refrigerant System Precautions

Covers R410A properties, proper piping, and system integrity.

4. Installation Location Selection

6. Unit Handling and Preparation

7. Refrigerant Piping

8. Refrigerant Piping Precautions

Connecting Refrigerant Piping

Describes procedures for connecting pipes to indoor and outdoor units, including knockout hole usage.

Handling Stop Valves

Details the correct usage, tightening torques, and precautions for stop valves.

9. Field Wiring

Power Circuit and Cable Requirements

Specifies power supply, safety devices, and cable types according to regulations.

10. Air Tight Test and Vacuum Drying

Air Tight Test and Vacuum Drying

Details the procedure for leak testing and removing moisture from the system.

12. Device and Installation Condition Checks

14. Refrigerant Charging

Refrigerant Charging Precautions

Covers essential safety and procedural warnings before charging refrigerant.

Calculating Additional Refrigerant Charge

Provides formulas and tables for determining the correct refrigerant amounts.

Adding Refrigerant Methods

Explains automatic and manual charging procedures, including flow charts.

15. Start-up and Configuration

Pre-Start-up Checks

Lists critical checks to perform before powering up the unit.

Test Operation

Outlines the procedure for verifying system functionality and troubleshooting.