How to fix Daikin REYQ14T7Y1B ambient temperature sensor malfunction?
- EEdward LewisSep 23, 2025
If the ambient temperature sensor is malfunctioning on your Daikin Air Conditioner, check the connection on the PCB or actuator.

How to fix Daikin REYQ14T7Y1B ambient temperature sensor malfunction?
If the ambient temperature sensor is malfunctioning on your Daikin Air Conditioner, check the connection on the PCB or actuator.
What to do if my Daikin REYQ14T7Y1B Air Conditioner shows a low pressure malfunction?
If your Daikin Air Conditioner is showing a low pressure malfunction, first open the stop valves. Then, check the refrigerant level and recharge the unit if needed. Finally, inspect the user interface display and the transmission wiring between the outdoor and indoor units.
How to fix a Daikin REYQ14T7Y1B Air Conditioner indoor unit communication error?
If you experience an indoor unit communication error with your Daikin Air Conditioner, check the user interface connection.
How to troubleshoot a Daikin REYQ14T7Y1B with an activated high pressure switch?
If the high pressure switch is activated on your Daikin Air Conditioner, check the stop valve situation and inspect for any abnormalities in the field piping or airflow over the air-cooled coil.
What to do if my Daikin REYQ14T7Y1B Air Conditioner has a refrigerant overcharge or stop valve closed?
If your Daikin Air Conditioner indicates a refrigerant overcharge or a closed stop valve, check the refrigerant amount and recharge the unit if necessary. Also, ensure that the stop valves are open.
How to troubleshoot Daikin REYQ14T7Y1B electronic expansion valve (lower heat exchanger)?
If you are experiencing issues with the electronic expansion valve (lower heat exchanger) (Y3E) on your Daikin Air Conditioner, check the connection on the main PCB (X23A) or the actuator.
How to troubleshoot Daikin REYQ14T7Y1B electronic expansion valve (receiver gas)?
If you are experiencing issues with the electronic expansion valve (receiver gas) (Y4E) on your Daikin Air Conditioner, check the connection on the main PCB (X25A) or the actuator.
How to troubleshoot Daikin REYQ14T7Y1B electronic expansion valve (subcool heat exchanger)?
If you are experiencing issues with the electronic expansion valve (subcool heat exchanger) (Y2E) on your Daikin Air Conditioner, check the connection on the main PCB (X22A) or the actuator.
What to do if stop valve closed during Daikin REYQ14T7Y1B system test run?
If the stop valve is closed or wrong during the system test run of your Daikin Air Conditioner, open the stop valves.
How to open a closed liquid stop valve on a Daikin REYQ14T7Y1B?
If the liquid stop valve is closed on your Daikin Air Conditioner, open the liquid stop valve.
| Brand | Daikin |
|---|---|
| Model | REYQ14T7Y1B |
| Category | Air Conditioner |
| Language | English |
Specifications and precautions for refrigerant piping installation.
Specifications and precautions for refrigerant piping installation.
Guidance on choosing the correct piping diameter based on unit capacity.
Procedure for selecting appropriate refrigerant branch kits.
Guidelines for routing and connecting piping for multiple outdoor units.
Overview of procedures for checking refrigerant piping installation.
Overview of procedures for checking refrigerant piping installation.
General guidelines for checking refrigerant piping.
Setup procedures for checking refrigerant piping, including valve states.
Steps for conducting a leak test on the refrigerant piping.
Procedure for vacuum drying the refrigerant piping system.
Safety precautions and warnings before charging refrigerant.
Safety precautions and warnings before charging refrigerant.
Overview of methods for charging additional refrigerant.
Method for calculating the required additional refrigerant charge.
Flowchart illustrating refrigerant charging procedures and options.
Detailed steps for charging refrigerant, including pre-charging and automatic/manual charging.
Procedure for automatic refrigerant charging with system limitations.
Procedure for manual refrigerant charging operation.
List and explanation of error codes encountered during refrigerant charging.
Final checks to be performed after refrigerant charging.
Procedure for connecting the main power supply to the unit.
Information on the automatic leak detection feature and its activation.
Information on the automatic leak detection feature and its activation.
Important safety precautions to observe before commissioning.
A checklist of items to verify before starting the commissioning process.
Overview of the test operation procedure and its objectives.
Step-by-step guide for performing the system test run.
Guide to resolving issues using malfunction codes and error tables.
A table listing and explaining various error codes and their causes.
Information about the refrigerant type, GWP, and handling precautions.
Recommendations for regular maintenance and inspection of the unit.
List and explanation of error codes appearing on the user interface.