Si011281E Electrical Components
Removal Procedure 7
2. Remove the electrical
component ASSY.
Compressor motor capacitor
(C1)
1
Pull out all the 3
terminals from the
compressor motor
capacitor (C1).
2
Pull out the terminal
(white: 3_lower) from
the terminal board
(X1M).
3
Remove the screw and
remove the electrical
component ASSY.
Step Procedure Points
Compressor motor capacitor
Terminal board
(R18997)
white, 3 lower
(R19151)
(R19011)
to compressor (S): red
to compressor (R): blue
to terminal board
(2_upper): blue
Electrical component ASSY
(R18999)
(R19000)
Compressor motor capacitor
Terminal
board
Fan motor capacitor