REMOVAL
PROCEDURE
SERVICE MANUAL
1.5/2.0/2.5/3.0/3.5 kW Class
9000/12000 Btu/h Class
Outdoor Unit
Inverter
Pair Type
Si001560EB
Question and Answer IconNeed help?

Do you have a question about the Daikin RKC35QVM and is the answer not in the manual?

Daikin RKC35QVM Specifications

General IconGeneral
Cooling Capacity3.5 kW
Heating Capacity4.0 kW
Power Supply220-240 V, 50 Hz
RefrigerantR32
Indoor Unit Weight9 kg
Outdoor Unit Weight32 kg
Noise Level (Outdoor Unit)48 dB

Summary

Outer Panels Removal

Outdoor Fan and Motor Removal

Electrical Box Component Disconnection

Disconnect Four Way Valve Coil Connector

Disconnect the connector [S80] for the four way valve coil.

Disconnect Electronic Expansion Valve Coil Connector

Disconnect the connector [S20] for the electronic expansion valve coil.

Thermistor Assembly Removal

Discharge Pipe Temperature Thermistor Removal

Pull out the discharge pipe temperature thermistor.

Outdoor Heat Exchanger Thermistor Removal

Pull out the outdoor heat exchanger thermistor and remove the ASSY.

Compressor Removal Procedure

Remove Compressor Protection Bushing and Wiring

Remove protection bushing and disconnect compressor lead wires/overload protector.

Heat and Disconnect Compressor Pipes

Heat brazed parts of discharge and suction pipes and disconnect them.