1. Outer Panels

Remove Top Panel and Screws

Remove the 4 screws and then the top panel.

Remove Front Panel Screws

Remove the 7 screws of the front panel.

2. Outdoor Fan / Fan Motor

3. Electrical Box

4. PCBs

5. Thermistor ASSY

Release Outdoor Temp Thermistor Wire

Pull out holder and release thermistor wire from slit.

Pull Out Heat Exchanger Thermistor

Pull out the outdoor heat exchanger thermistor.

6. Partition Plate / Sound Blankets

7. Electronic Expansion Valve

Pull Out Expansion Valve Coil

Pull out the electronic expansion valve coil.

Remove Electronic Expansion Valve

Heat brazed parts and remove the electronic expansion valve.

8. Four Way Valve

Remove Four Way Valve Coil

Remove the screw and then the four way valve coil.

Remove Four Way Valve

Heat brazed parts and remove the four way valve.

9. Compressor

Disconnect Compressor Wires

Disconnect compressor lead wires (U, V, W) and overload protector.

Disconnect Discharge Side Pipe

Heat brazed part of discharge side pipe and disconnect it.

Disconnect Suction Side Pipe

Heat brazed part of suction side pipe and disconnect it.

Remove Compressor

Lift up the compressor and remove it.