Do you have a question about the Daikin RKC71QVM and is the answer not in the manual?
Category | Air Conditioner |
---|---|
Cooling Capacity | 7.1 kW |
Heating Capacity | 8.0 kW |
Power Supply | 220-240 V, 50 Hz |
Refrigerant | R32 |
Function | Cooling and Heating |
Remove the 4 screws and then the top panel.
Remove the 7 screws of the front panel.
Pull out holder and release thermistor wire from slit.
Pull out the outdoor heat exchanger thermistor.
Pull out the electronic expansion valve coil.
Heat brazed parts and remove the electronic expansion valve.
Remove the screw and then the four way valve coil.
Heat brazed parts and remove the four way valve.
Disconnect compressor lead wires (U, V, W) and overload protector.
Heat brazed part of discharge side pipe and disconnect it.
Heat brazed part of suction side pipe and disconnect it.
Lift up the compressor and remove it.