Main Functions SiBE041010EA
21 Function and Control
1.3 Airflow Direction Control
Power-Airflow
Flap
The large flap sends a large volume of air downward to the floor and provides an optimum
control in cooling, dry, and heating operation.
<Cooling / Dry>
During cooling or dry operation, the flap retracts into the indoor unit. Then, cool air can be blown
far and distributed all over the room.
<Heating>
During heating operation, the large flap directs airflow downward to spread the warm air to the
entire room.
Wide-Angle
Louvers
The louvers, made of elastic synthetic resin, provide a wide range of airflow that guarantees
comfortable air distribution.
Auto-Swing The following table explains the auto-swing process for cooling, dry, fan, and heating:
COMFORT
AIRFLOW
Operation
The vertical swing flap is controlled not to blow the air directly at the people in the room.
Vertical Swing (up and down)
Cooling / Dry / Fan Heating
(R11256)
45˚
(R11257)
15˚
45˚
Cooling / Dry Heating
(R11259)
(R11258)
50˚