EasyManua.ls Logo

Daikin RXQ40AMYM User Manual

Daikin RXQ40AMYM
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
HQWUHRIUDYLW
540540540540
8QLWPP
(17(52)
)2817,21
%2/7+2/(6/27
(17(52)
)2817,21
%2/7+2/(6/27





(17(52)
)2817,21
%2/7+2/(
(17(52)
)2817,21
%2/7+2/(
(17(52)
)2817,21
%2/7+2/(

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Daikin RXQ40AMYM and is the answer not in the manual?

Daikin RXQ40AMYM Specifications

General IconGeneral
BrandDaikin
ModelRXQ40AMYM
CategoryInverter
LanguageEnglish

Summary

General Safety Precautions

DANGER: Do Not Touch Piping and Internal Parts

Specific safety warning about touching hot/cold piping and internal parts during or immediately after operation.

Special Product Notices

Special Notice of Product

Specific precautions related to R410A refrigerant and design pressure requirements.

Installation Location Selection

General Precautions on Installation

Outlines requirements for selecting a suitable and safe installation site.

Unit Inspection and Installation

Installing the Unit

Instructions for ensuring the unit is level and securely mounted on a strong base.

Piping Size and Branch Kit Selection

Selection of Refrigerant Branch Kits

Guides on selecting REFNET joints and headers based on system configuration.

System Piping Length Limitations

Piping Length Restrictions

Details maximum allowable lengths and level differences for piping.

Multi System Piping Installation

Precautions for Connecting Piping Between Outdoor Units

Safety and installation notes for connecting multiple outdoor units.

Refrigerant Piping Precautions

Caution for Brazing

Emphasizes safety and proper techniques for brazing refrigerant pipes.

Leak Test and Vacuum Drying Procedures

General Guidelines

Essential initial steps and warnings before leak testing and vacuum drying.

Regular Installation Method

Detailed procedure for leak testing and vacuum drying before powering up.

After Electrical Installation Method

Procedure for leak testing and vacuum drying after electrical installation.

Leak Test, Vacuum Drying, and Pipe Insulation

Leak Test

Specific methods for performing vacuum and pressure leak tests.

Vacuum Drying

Steps to remove moisture from the system using vacuum drying.

Electrical Wiring Work

Precautions on Electrical Wiring Work

Critical safety warnings and requirements for electrical installation.

Wiring System and Requirements

Requirements

Specifies electrical protection and wiring size requirements based on standards.

Knockout Holes and Wiring Connections

Connection of Transmission Wiring

Illustrates how to connect transmission wiring for single and multi-unit systems.

Wiring Terminal Connections

Connection of Wiring to Terminals

Details on connecting power and transmission wiring to terminal blocks.

Making Field Settings

Operating Push Buttons and DIP Switches

Guides on using buttons and switches for system configuration.

Refrigerant Charging

Precautions

Essential safety precautions before and during refrigerant charging.

Calculating Additional Refrigerant Charge

Provides formulas and tables for calculating necessary refrigerant amounts.

Method for Adding Refrigerant

Flow Chart

Visual guide outlining the steps for adding refrigerant to the system.

Monitoring and Field Settings

Mode 2

Details how to use Mode 2 for changing field settings and system configurations.

Test Run Procedures

Test Operation

Procedures for performing a system test run after installation.

Precautions Before Starting Test Operation

Safety warnings and essential preparations before starting the test run.

Test Operation Execution

Step-by-step guide for executing the automatic system test operation.

Correcting Abnormal Test Operation

How to address and resolve issues identified during the test operation.

Malfunction Code Interpretation

Malfunction Code List

Explains how to interpret and correct displayed malfunction codes.

Service Precautions for Specific Models

Caution for Service Inside EL.COMPO.BOX

Specific safety warnings for working inside the electrical component box.

Operational Checks and Refrigerant Charging

Service Precautions (Part 2)

Additional Refrigerant Charging

Additional Refrigerant Charging Operation

Detailed procedure for charging additional refrigerant, including automatic methods.

System Check Operation

Check Operation Method

Summarizes the automatic system check operation and its results.

Service Mode Operation

Service Mode Operation Method

Explains how to access and use service modes for evacuation and refrigerant recovery.

Unit Installation and Moving Guidelines

Electrical Work

Essential electrical safety practices, including grounding.

Appendix: Refrigerant Leak Cautions

Caution for Refrigerant Leaks

General information and warnings about refrigerant leaks.

Refrigerant Leak Concentration Check

Maximum Refrigerant Concentration Procedure

Related product manuals