INSTALLATION
MANUAL
R410A Split Series
Models
RXS20CVMB RKS20CVMB
RXS25CVMB RKS25CVMB
RXS35CVMB RKS35CVMB
ARXS20CVMB ARKS20CVMB
ARXS25CVMB ARKS25CVMB
ARXS35CVMB ARKS35CVMB
RXS20C2VMB RKS20C2VMB
RXS25C2VMB RKS25C2VMB
RXS35C2VMB RKS35C2VMB
ARXS20C2VMB ARKS20C2VMB
ARXS25C2VMB ARKS25C2VMB
ARXS35C2VMB ARKS35C2VMB
RXG25CVMB RXG25E2V1B
RXG35CVMB RXG35E2V1B
ARXG25CVMB ARXG25E2V1B
ARXG35CVMB ARXG35E2V1B
Deutsch
Français
Nederlands
Español
Italiano
ΕλληνικÜ
Portugues
Рóссêий
English
Türkçe
Installation manual
R410A Split series
Montaj kýlavuzlarý
R410A Split serisi
Installationsanleitung
Split-Baureihe R410A
Manuel d’installation
Série split R410A
Montagehandleiding
R410A Split-systeem
Manual de instalación
Serie Split R410A
Manuale d’installazione
Serie Multiambienti R410A
Εγχειρßδιο εγκατÜστασηò
διαιροýìενηò σειρÜò R410A
Manual de Instalação
Série split R410A
Рóêоводство по монтажó
Серия R410A с раздельной óстановêой
00_CV_3P119321-7W.fm Page 1 Thursday, March 8, 2007 5:43 PM

Other manuals for Daikin RXS20CVMB

Questions and Answers

  • M
    Michelle CampbellAug 12, 2025
    Why is my Daikin RXS20CVMB outdoor unit leaking water?
    • R
      Rachel MorenoAug 13, 2025
      In HEAT mode, the frost on the outdoor unit melts into water or steam during defrost operation. In COOL or DRY mode, moisture in the air condenses into water on the cool surface of the outdoor unit piping and drips.
  • A
    Allison WrightAug 16, 2025
    Why does my Daikin RXS20CVMB smell?
    • T
      tracyskinnerAug 17, 2025
      The Daikin Air Conditioner may emit odors because smells from the room, furniture, or cigarettes have been absorbed into the unit and are being discharged with the airflow. It is recommended to have the indoor unit cleaned by a technician. Consult the service shop where you bought the air conditioner.
  • S
    Steve JarvisAug 20, 2025
    What to do if my Daikin Air Conditioner heating stops suddenly?
    • D
      donna05Aug 20, 2025
      The system is likely removing frost from the outdoor unit. You should wait for about 3 to 8 minutes.
  • C
    Carrie FlynnAug 25, 2025
    Why doesn't hot air come out immediately from my Daikin RXS20CVMB when heating?
    • J
      Joshua RiceAug 25, 2025
      You should wait for 1 to 4 minutes. The system is designed to start discharging air only after it has reached a certain temperature.
  • K
    Katie HernandezAug 27, 2025
    Why my Daikin Air Conditioner does not start immediately?
    • H
      hrodriguezAug 28, 2025
      If the ON/OFF button was pressed soon after operation was stopped, or if the mode was reselected, you should wait for about 3 minutes.
  • D
    Dawn GilbertAug 31, 2025
    What to do if my Daikin RXS20CVMB operation stopped suddenly?
    • M
      Michelle CastilloSep 1, 2025
      For system protection, the air conditioner may stop operating due to a sudden large voltage fluctuation. It will automatically resume operation in about 3 minutes.
  • J
    Jacqueline HillSep 4, 2025
    Why is the Daikin RXS20CVMB Air Conditioner outdoor fan running when it's off?
    • E
      Elizabeth TorresSep 4, 2025
      After operation is stopped, the outdoor fan may continue rotating for another 60 seconds for system protection. Also, when the outdoor temperature is very high, the outdoor fan might start rotating for system protection even when the air conditioner is not in operation.
  • A
    Angel LewisSep 8, 2025
    Why does mist come out of my Daikin RXS20CVMB Air Conditioner?
    • C
      Christopher Williams DDSSep 8, 2025
      This happens when the air in the room is cooled into mist by the cold air flow during cooling operation.

Summary

Safety and Compliance

General Safety Precautions

Overall safety guidelines highlighting the importance of following WARNING and CAUTION.

Safety Warnings

Critical warnings indicating severe risks like death or injury if ignored.

Safety Cautions

Important cautions highlighting potential grave consequences if ignored.

Outdoor Unit Installation

Purging Air and Checking Gas Leakage

Process for removing air from the system and performing leak checks for refrigerant.

Special Operations and Wiring

Wiring Process

Detailed steps for connecting electrical wires between indoor and outdoor units.

Wiring Cautions

Important warnings and precautions to prevent electrical hazards during wiring.

Final Checks and Testing

Test Run and Final Check

Procedures for verifying proper installation and system functionality through testing.

Daikin RXS20CVMB Specifications

General IconGeneral
Cooling Capacity2.0 kW
Heating Capacity2.5 kW
TypeSplit System
Power Supply220-240V, 50Hz
Indoor Unit Noise Level21 dB(A)