SiEBE04-507A
Service Manual
/ Inverter Pair Wall Mounted Type D-Series
SiENBE04-507A
Ser vice
Manual
[Applied Models]
!Inverter Pair : Cooling Only
!Inverter Pair : Heat Pump
Inverter Pair
Wall Mounted Type D-Series
Daikin Europe N.V. participates in the Eurovent
Certification Programme for Air Conditioners (AC),
Liquid Chilling Packages (LCP) and Fan Coil Units (FC);
the certified data of certified models are listed in the
Eurovent Directory.
ISO14001 assures an effective environmental
management system in order to help protect human
health and the environment from the potential impact
of our activities, products and services and to assist in
maintaining and improving the quality of the
environment.
Daikin Europe N.V. is approved by LRQA for its Quality
Management System in accordance with the ISO9001
standard. ISO9001 pertains to quality assurance
regarding design, development, manufacturing as well
as to services related to the product.
Daikin units comply with the European regulations that
guarantee the safety of the product.
SiENBE04-507A • 06/2007 • Copyright © Daikin
Printed in Belgium by Lannoo, a company whose concern for the environment
is set in the EMAS and ISO 14001 systems. www.lannooprint.be
ÉSiENBE04-507AÄËÍ
Naamloze Vennootschap
Zandvoordestraat 300
B-8400 Oostende - Belgium
www.daikin.eu
BTW: BE 0412 120 336
RPR Oostende
"The present publication is drawn up by way of information only
and does not constitute an offer binding upon Daikin Europe N.V..
Daikin Europe N.V. has compiled the content of this publication to
the best of its knowledge. No express or implied warranty is given
for the completeness, accuracy, reliability or fitness for particular
purpose of its content and the products and services presented
therein. Specifications are subject to change without prior notice.
Daikin Europe N.V. explicitly rejects any liability for any direct or
indirect damage, In the broadest sense, arising from or related to
the use and/or interpretation of this publication. All content is
copyrighted by Daikin Europe N.V.."
Daikin’s unique position as a manufacturer of air
conditioning equipment, compressors and
refrigerants has led to its close involvement in
environmental issues.
For several years Daikin has had the intension to
become a leader in the provision of products
that have limited impact on the environment.
This challenge demands the eco design and
development of a wide range of products and
an energy management system, resulting in
energy conservation and a reduction of waste.

Table of Contents

Questions and Answers

  • W
    William FrazierAug 19, 2025
    What to do if my Daikin RXS25DVMB operation stops suddenly and the OPERATION lamp flashes?
    • K
      Karl GonzalezAug 19, 2025
      If the OPERATION lamp on your Daikin Air Conditioner is flashing and the operation stops suddenly, clean the air filters or remove any obstructions. Then, turn the breaker OFF and then ON again. Try operating the air conditioner with the remote controller. If the lamp continues to flash, no answer.
  • C
    Christopher GuzmanAug 21, 2025
    Why does my Daikin Air Conditioner emit water or steam?
    • E
      erinhendrixAug 21, 2025
      In HEAT mode, the frost on the outdoor unit melts into water or steam when the air conditioner is in defrost operation. In COOL or DRY mode, moisture in the air condenses into water on the cool surface of outdoor unit piping and drips.
  • C
    christopherbarnettAug 23, 2025
    What to do if my Daikin RXS25DVMB indoor unit smells bad?
    • M
      Marc RobertsAug 23, 2025
      If your Daikin Air Conditioner's indoor unit is emitting an odor, it is recommended to have the indoor unit cleaned by a technician.
  • J
    Jasmine ArellanoAug 26, 2025
    What to do if hot air does not flow out soon after starting my Daikin RXS25DVMB's heating operation?
    • J
      Jillian StevensAug 26, 2025
      You should wait for 1 to 4 minutes.
  • D
    Darlene ThompsonAug 28, 2025
    Why do mists come out of the indoor unit of my Daikin RXS25DVMB?
    • M
      Michael PaulAug 28, 2025
      This happens when the air in the room is cooled into mist by the cold air flow during cooling operation.
  • S
    Stacie ChristensenAug 30, 2025
    How to handle odour from the indoor unit of my Daikin Air Conditioner?
    • D
      David BergerAug 30, 2025
      If this happens, we recommend you have the indoor unit washed by a technician. Consult the service shop where you bought the air conditioner.
  • T
    taylorannaSep 2, 2025
    Why is my Daikin RXS25DVMB Air Conditioner outdoor unit emitting water or steam?
    • V
      vjimenezSep 2, 2025
      If your Daikin Air Conditioner's outdoor unit is emitting water or steam, this is normal. In HEAT mode, frost on the outdoor unit melts into water or steam during defrost operation. In COOL or DRY mode, moisture in the air condenses into water on the cool surface of the outdoor unit piping and drips.
  • R
    Richard CunninghamSep 4, 2025
    Why does mist come out of my Daikin RXS25DVMB Air Conditioner indoor unit?
    • R
      rhowardSep 4, 2025
      Mists coming out of the Daikin Air Conditioner's indoor unit can occur when the air in the room is cooled into mist by the cold airflow during cooling operation.
  • P
    Patricia MartinSep 6, 2025
    Why does the outdoor fan on my Daikin RXS25DVMB Air Conditioner keep running when it's off?
    • S
      Stacey SwansonSep 6, 2025
      If the outdoor fan of your Daikin Air Conditioner rotates even when the unit is not in operation, this is normal. After stopping the operation, the fan may continue rotating for 60 seconds for system protection. Also, when the outdoor temperature is very high, the fan might start rotating for system protection.
  • E
    Elijah ThomasSep 8, 2025
    What to do if my Daikin RXS25DVMB Air Conditioner operation stopped suddenly but the OPERATION lamp is on?
    • J
      James YatesSep 8, 2025
      If your Daikin Air Conditioner stops suddenly and the OPERATION lamp is on, it will automatically resume operation in about 3 minutes.

Summary

List of Functions

List of Functions

Provides a comprehensive list of all functions available for the Daikin Inverter Pair Wall Mounted Type D-Series units.

Specifications

Specifications

Details technical specifications for Cooling Only models, including capacity, power, airflow, and dimensions.

Printed Circuit Board Connector Wiring Diagram

Printed Circuit Board Connector Wiring Diagram

Illustrates the connector layout for both indoor and outdoor unit PCBs, essential for service and troubleshooting.

Function and Control

Main Functions

Explains the primary operating functions and principles of the air conditioning system.

System Configuration

System Configuration

Outlines the overall system setup and user instructions after installation.

Service Diagnosis

Caution for Diagnosis

Provides essential warnings and guidelines before performing diagnostic procedures.

Removal Procedure

Indoor Unit

Step-by-step instructions for disassembling various components of the indoor unit.

Others

Others

Covers miscellaneous topics such as test runs and jumper settings.

Appendix

Piping Diagrams

Visual representations of the refrigerant piping circuits for indoor and outdoor units.

Daikin RXS25DVMB Specifications

General IconGeneral
Cooling Capacity2.5 kW
RefrigerantR32
Heating Capacity3.2 kW
Star Rating (Cooling)5
Power Supply220-240 V, 50 Hz
Indoor Unit Noise Level19 dB(A)