INSTALLATION
MANUAL
R410A Split Series
Models
RXS20CVMB RKS20CVMB
RXS25CVMB RKS25CVMB
RXS35CVMB RKS35CVMB
ARXS20CVMB ARKS20CVMB
ARXS25CVMB ARKS25CVMB
ARXS35CVMB ARKS35CVMB
RXS20C2VMB RKS20C2VMB
RXS25C2VMB RKS25C2VMB
RXS35C2VMB RKS35C2VMB
ARXS20C2VMB ARKS20C2VMB
ARXS25C2VMB ARKS25C2VMB
ARXS35C2VMB ARKS35C2VMB
RXG25CVMB RXG25E2V1B
RXG35CVMB RXG35E2V1B
ARXG25CVMB ARXG25E2V1B
ARXG35CVMB ARXG35E2V1B
Deutsch
Français
Nederlands
Español
Italiano
ΕλληνικÜ
Portugues
Рóссêий
English
Türkçe
Installation manual
R410A Split series
Montaj kýlavuzlarý
R410A Split serisi
Installationsanleitung
Split-Baureihe R410A
Manuel d’installation
Série split R410A
Montagehandleiding
R410A Split-systeem
Manual de instalación
Serie Split R410A
Manuale d’installazione
Serie Multiambienti R410A
Εγχειρßδιο εγκατÜστασηò
διαιροýìενηò σειρÜò R410A
Manual de Instalação
Série split R410A
Рóêоводство по монтажó
Серия R410A с раздельной óстановêой
00_CV_3P119321-7W.fm Page 1 Thursday, March 8, 2007 5:43 PM

Other manuals for Daikin RXS25CVMB

Questions and Answers

  • L
    Lisa GrayAug 12, 2025
    Why is my Daikin RXS25CVMB outdoor unit leaking water?
    • E
      Edward GallegosAug 12, 2025
      In HEAT mode, the frost on the outdoor unit melts into water or steam during defrost operation. In COOL or DRY mode, moisture in the air condenses into water on the cool surface of the outdoor unit piping and drips.
  • J
    Jose HarrellAug 15, 2025
    Why does my Daikin Air Conditioner smell?
    • C
      chaneytiffanyAug 16, 2025
      The Daikin Air Conditioner may emit odors because smells from the room, furniture, or cigarettes have been absorbed into the unit and are being discharged with the airflow. It is recommended to have the indoor unit cleaned by a technician. Consult the service shop where you bought the air conditioner.
  • K
    Kristen ScottAug 19, 2025
    What to do if my Daikin Air Conditioner heating stops suddenly?
    • S
      Shawn DavisAug 19, 2025
      The system is likely removing frost from the outdoor unit. You should wait for about 3 to 8 minutes.
  • E
    Elizabeth SmithAug 23, 2025
    Why doesn't hot air come out immediately from my Daikin RXS25CVMB when heating?
    • C
      connie52Aug 23, 2025
      You should wait for 1 to 4 minutes. The system is designed to start discharging air only after it has reached a certain temperature.
  • B
    brenda67Aug 27, 2025
    Why my Daikin RXS25CVMB does not start immediately?
    • J
      James Solomon DDSAug 27, 2025
      If the ON/OFF button was pressed soon after operation was stopped, or if the mode was reselected, you should wait for about 3 minutes.
  • R
    Russell HuertaAug 31, 2025
    What to do if my Daikin Air Conditioner operation stopped suddenly?
    • J
      Jacob NavarroAug 31, 2025
      For system protection, the air conditioner may stop operating due to a sudden large voltage fluctuation. It will automatically resume operation in about 3 minutes.
  • L
    Lisa JenkinsSep 3, 2025
    Why is the Daikin Air Conditioner outdoor fan running when it's off?
    • A
      andrelynnSep 4, 2025
      After operation is stopped, the outdoor fan may continue rotating for another 60 seconds for system protection. Also, when the outdoor temperature is very high, the outdoor fan might start rotating for system protection even when the air conditioner is not in operation.
  • C
    Cynthia StewartSep 7, 2025
    Why does mist come out of my Daikin Air Conditioner?
    • T
      Tracy BlackSep 8, 2025
      This happens when the air in the room is cooled into mist by the cold air flow during cooling operation.

Summary

Safety Precautions

General Safety Warnings

Defines the severity of consequences for ignoring WARNING statements regarding safety.

General Safety Cautions

Defines the severity of consequences for ignoring CAUTION statements regarding safety.

Safety Symbols Guide

Explains the meaning of symbols used throughout the manual for safety instructions.

Precautions for Selecting the Location

Outdoor Unit Installation

Flaring the Pipe End

Step-by-step guide on how to properly flare the end of refrigerant pipes using specified tools.

Refilling The Refrigerant

Instructions on how to refill refrigerant, including precautions for R410A and filling methods.

Refrigerant Piping and Warnings

Details on connecting refrigerant pipes, applying oil, and warnings about mineral oil and reusing parts.

Purging Air and Checking Gas Leakage

Purging and Leak Check Procedure

Step-by-step instructions for purging air and checking for refrigerant leaks using a gauge manifold.

Pump Down Operation

Facility Setting

Wiring

General Wiring Warnings

Covers warnings about improper wiring, using non-specified parts, and the need for earth leak detectors.

Test Run and Final Check

Daikin RXS25CVMB Specifications

General IconGeneral
CategoryAir Conditioner
TypeSplit System
Cooling Capacity2.5 kW
Heating Capacity3.2 kW
Indoor Unit Weight9 kg
Power Supply220-240V, 50Hz
RefrigerantR32
Noise Level (Indoor Unit)19 dB

Related product manuals