Do you have a question about the Daikin RXS25E2V1B and is the answer not in the manual?
Model | RXS25E2V1B |
---|---|
Category | Air Conditioner |
Manufacturer | Daikin |
Cooling Capacity | 2.5 kW |
Heating Capacity | 3.2 kW |
Energy Efficiency Ratio (EER) | 3.21 |
Energy Efficiency Class (Cooling) | A |
Energy Efficiency Class (Heating) | A |
Power Supply | 220-240V |
Weight (Indoor Unit) | 9 kg |
Type | Split |
Seasonal Energy Efficiency Ratio (SEER) | 6.10 |
Power Supply (Voltage/Phase/Frequency) | 220-240V/1/50Hz |
Refrigerant | R32 |
Details safety precautions to be observed before and during repair work.
Explains the meaning of icons used throughout the manual for specific information.
Lists and describes the various functions available for the air conditioner.
Provides detailed technical specifications for the air conditioner models.
Specifies technical details for cooling-only operation of the units.
Specifies technical details for heat pump operation of the units.
Illustrates the connector layouts and identification for indoor and outdoor unit PCBs.
Details connectors for indoor unit PCBs: Control, Power Supply, Display, and Signal Receiver.
Details connectors for outdoor unit PCBs: Filter and Main PCBs.
Describes the primary functions and operational principles of the air conditioner.
Explains the mechanism and logic behind the temperature control system.
Details the inverter principle and compressor frequency control for optimal performance.
Explains the automatic mode for cooling/heating based on room temperature.
Outlines the system's control specifications and operational logic.
Details the process of determining and controlling compressor frequency.
Covers sensor malfunctions, overcurrent, and overload detection for troubleshooting.
Provides comprehensive instructions for operating the air conditioner.
Details the functions and operation of the remote control unit.
Explains how to select and operate different modes like AUTO, DRY, COOL, HEAT, and FAN.
Describes activating and canceling the POWERFUL operation for maximum capacity.
Explains how to set and use the HOME LEAVE operation for preferred settings.
Details the use of ON and OFF timer functions for automatic operation scheduling.
Provides essential safety cautions and guidelines before performing diagnostics.
Lists error codes, symptoms, and troubleshooting steps for diagnosing issues.
Lists all system error codes, their meanings, and corresponding troubleshooting pages.
Details troubleshooting for indoor unit PCB abnormalities (Error A1).
Explains troubleshooting for freeze-up protection and heating peak-cut control (Error A5).
Guides troubleshooting for fan motor abnormalities (Error A6).
Details troubleshooting for indoor unit thermistor abnormalities (Errors C4, C9).
Provides troubleshooting for signal transmission errors between units (Error U4).
Details troubleshooting for outdoor unit PCB abnormalities (Error E1).
Explains troubleshooting for OL activation or compressor overload (Error E5).
Guides troubleshooting for compressor lock issues (Error E6).
Explains troubleshooting for input overcurrent detection (Error E8).
Guides troubleshooting for four way valve abnormalities (Error EA).
Details troubleshooting for discharge pipe temperature control issues (Error F3).
Explains troubleshooting for high pressure control in cooling mode (Error F6).
Details troubleshooting for refrigerant shortage issues (Error U0).
Provides procedures for checking specific components and systems.
Details general methods for checking various parts and systems.
Provides step-by-step instructions for removing parts of the indoor unit.
Provides instructions for removing the electrical box and PCB from the indoor unit.
Explains how to remove the indoor heat exchanger.
Provides removal procedures for the RK(X)S25/35E2V1B outdoor unit.
Details how to remove outer panels and the fan motor of the outdoor unit.
Explains how to remove the electrical box from the outdoor unit.
Provides instructions for removing the main PCB from the outdoor unit.
Provides instructions for removing the four-way valve.
Details the procedure for removing the compressor.
Provides removal procedures for the RK(X)S25/35G2V1B outdoor unit.
Details how to remove outer panels and the fan motor of the outdoor unit.
Explains how to remove the electrical box from the outdoor unit.
Provides instructions for removing the main PCB from the outdoor unit.
Provides instructions for removing the four-way valve.
Details the procedure for removing the compressor.
Provides removal procedures for the RK(X)S25/35G2V1B9 outdoor unit.
Details how to remove outer panels and the fan motor of the outdoor unit.
Explains how to remove the electrical box from the outdoor unit.
Provides instructions for removing the main PCB from the outdoor unit.
Provides instructions for removing the four-way valve.
Details the procedure for removing the compressor.
Explains the procedure for performing trial operation of the air conditioner.
Covers various field settings required for proper operation and configuration.
Describes the facility setting jumper for expanding operation range to low temperatures.
Provides instructions for applying silicon grease for heat radiation on PCB components.
Contains diagrams illustrating the refrigerant piping connections for indoor and outdoor units.
Contains wiring diagrams for the indoor and outdoor units.