Do you have a question about the Daikin RXS25F2V1B and is the answer not in the manual?
Cooling Capacity | 2.5 kW |
---|---|
Heating Capacity | 3.2 kW |
Power Supply | 230V/1ph/50Hz |
Weight (Indoor Unit) | 9 kg |
Refrigerant | R32 |
Indoor Unit Weight | 9 kg |
Provides essential safety precautions for repair work, classifying items into Warning and Caution categories.
Illustrates the wiring diagrams for printed circuit boards.
Provides wiring diagrams for the indoor unit's PCBs and connectors.
Provides wiring diagrams for the outdoor unit's PCBs and connectors.
Explains how frequency is determined and controlled for compressor operation.
Explains the switching operation of the four-way valve during different modes.
Details compensation for four-way valve operation based on frequency.
Explains compressor protection limits based on frequency.
Details control mechanisms based on discharge pipe temperature.
Explains how input current is monitored and used for frequency control.
Describes the freeze-up protection control during cooling operation.
Details heating peak-cut control to prevent abnormal high pressure.
Details the protection function against liquid compression for the compressor.
Explains the defrosting process carried out by the cooling cycle.
Details the control logic for the electronic expansion valve.
Provides essential cautions before performing diagnostic procedures.
Explains how to troubleshoot using LED indicators on the indoor and outdoor units.
Lists common operational problems and their corresponding troubleshooting measures.
Provides a comprehensive guide to troubleshooting system errors.
Lists and describes all error codes displayed by the system.
Details troubleshooting steps for indoor unit PCB abnormalities.
Troubleshooting for freeze-up protection and heating peak-cut control issues.
Troubleshooting steps for fan motor abnormalities and related issues.
Troubleshooting for indoor unit thermistor abnormalities and related faults.
Troubleshooting steps for signal transmission errors between units.
Troubleshooting for unspecified voltage issues between units.
Troubleshooting steps for outdoor unit PCB abnormalities.
Troubleshooting for OL activation or compressor overload.
Troubleshooting steps for compressor lock conditions.
Troubleshooting for DC fan lock errors.
Troubleshooting for input overcurrent detection.
Troubleshooting steps for four-way valve abnormalities.
Troubleshooting related to discharge pipe temperature control.
Troubleshooting for high pressure control issues during cooling operation.
Troubleshooting for compressor system sensor abnormalities.
Troubleshooting for position sensor abnormalities.
Troubleshooting for DC voltage/current sensor abnormalities in 25/35 class units.
Troubleshooting for CT or related abnormalities in 50 class units.
Troubleshooting for outdoor unit thermistor abnormalities.