EasyManua.ls Logo

Daikin RXS42G2V1B User Manual

Daikin RXS42G2V1B
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SiENBE04-808_A
Service
Manual
Inverter Pair
Wall Mounted Type G-Series
[Applied Models]
z
Inverter Pair: Cooling only
z
Inverter Pair: Heat Pump
SiENBE04-808_A.pdf 1 21/02/2011 13:19:48

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Daikin RXS42G2V1B and is the answer not in the manual?

Daikin RXS42G2V1B Specifications

General IconGeneral
ModelRXS42G2V1B
CategoryHeat Pump
Cooling Capacity4.2 kW
Heating Capacity5.0 kW
Energy Efficiency Ratio (EER)3.21
Seasonal Energy Efficiency Ratio (SEER)6.1
Heating Seasonal Performance Factor (HSPF)4.0
Outdoor Unit Dimensions (W x H x D)800 x 550 x 285 mm
Weight (Indoor Unit)10 kg
RefrigerantR32
Power Supply230V/50Hz

Summary

Part 1 List of Functions

1. Functions: Cooling Only and Heat Pump

Lists functions for Cooling Only and Heat Pump models.

Part 5 Operation Manual

1. System Configuration

Explains how to operate and handle the air conditioner after installation.

2. FTXS Series Operation

Details remote control and operational modes for FTXS series.

3. ATXS Series Operation

Details remote control and operational modes for ATXS series.

Part 6 Service Diagnosis

1. Caution for Diagnosis

Safety precautions and troubleshooting guidance for diagnosis.

2. Problem Symptoms and Measures

Lists common symptoms and troubleshooting steps.

3. Service Check Function

Procedures for using remote control check functions (ARC452/ARC433).

Part 7 Removal Procedure

1. Indoor Unit Removal Procedures

Step-by-step guide for removing indoor unit components.

2. Outdoor Unit RK(X)S20-35G2V1B, ARXS20-35G2V1B Removal

Procedures for removing outer panels and fan motor.

3. Outdoor Unit RK(X)S20-35G2V1B9, ARXS20-35G3V1B Removal

Procedures for removing outer panels and fan motor.

4. Outdoor Unit RK(X)S42G2V1B, ARXS42G2V1B Removal

Procedures for removing outer panels and fan motor.

5. Outdoor Unit RK(X)S50G2V1B, ARXS50G2V1B Removal

Procedures for removing outer panels and fan motor.

Part 2 Specifications

1. Specifications: Cooling Only

Provides technical specifications for Cooling Only models.

Part 4 Function and Control

1. Main Functions: Frequency Principle

Explains the inverter principle and frequency control.

2. Function of Thermistor

Details the role of various thermistors in system control.

3. Control Specification: Mode Hierarchy

Outlines the different operation modes and their hierarchy.

Part 8 Trial Operation and Field Settings

1. Trial Operation

Steps for conducting trial operation on the air conditioner.

2. Field Settings: Model Type and Room Configuration

Settings for model type, multiple units in one room, and standby saving.

3. Silicon Grease Application for Heat Radiation

Guide for applying silicon grease to PCB components for heat dissipation.

Part 9 Appendix

1. Piping Diagrams: Indoor and Outdoor Units

Diagrams illustrating refrigerant flow for indoor and outdoor units.

2. Wiring Diagrams: Indoor and Outdoor Units

Electrical wiring diagrams for indoor and outdoor units.

Related product manuals