SiBE06-708_A Outdoor Unit - RK(X)S50F2V1B, RK(X)S50G2V1B
Removal Procedure 236
5.2 Removal of Outdoor Fan / Fan Motor
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure Points
1. Remove the electrical box
cover.
Preparation
Remove the top panel and
the front panel according to
the “Removal of Outer
Panels”.
This procedure is not
necessary to remove the
outdoor fan only.
1
Remove the screw of
the shield plate.
2
Unfasten the 2 hooks
and remove the shield
plate.
3
Unfasten the 4 hooks of
the electrical box cover
and remove it.
(R5255)
Shield plate
Hook
(R12029)
Electrical
box cover
(R5257)

Table of Contents