4 Unit installation
Installation manual
11
RXTM30+40N2V1B + RXTP25+35N2V1B9 +
RXTP25+35N2V1B8 + ARXTP25+35N2V1B + RXTA30N2V1B
R32 split series
3P482320-10S – 2020.08
>150
>50
>300
(mm)
b
a
>100
>50
>150
>50
b
b
a
>100
b
a
a
b
a
>100
a Air outlet
b Air inlet
NOTICE
The height of the wall on the outlet side of the outdoor unit
MUST be ≤1200mm.
It is recommended to install a baffle plate when the air outlet is
exposed to wind.
It is recommended to install the outdoor unit with the air inlet facing
the wall and NOT directly exposed to the wind.
b
a
b
c
a Baffle plate
b Prevailing wind direction
c Air outlet
Do NOT install the unit in sound sensitive areas (e.g. near a
bedroom), so that the operation noise will cause no trouble.
Note: If the sound is measured under actual installation conditions,
the measured value might be higher than the sound pressure level
mentioned in "Sound spectrum" in the data book due to
environmental noise and sound reflections.
Do NOT install the unit in sound sensitive areas (e.g. near a
bedroom), so that the operation noise will cause no trouble.
INFORMATION
The sound pressure level is less than 70dBA.
The outdoor unit is designed for outdoor installation only, and for
ambient temperatures within the following ranges:
Cooling mode Heating mode
–10~46°C DB –25~24°C DB
4.1.2 Additional installation site requirements
of the outdoor unit in cold climates
Protect the outdoor unit against direct snowfall and take care that the
outdoor unit is NEVER snowed up.
a
b
c
c
d
a Snow cover or shed
b Pedestal
c Prevailing wind direction
d Air outlet
It is recommended to provide at least 150mm of free space below
the unit (300mm for heavy snowfall areas). Additionally, make sure
the unit is positioned at least 100mm above the maximum expected
level of snow. If necessary, construct a pedestal. See "4.2Mounting
the outdoor unit"[411] for more details.
In heavy snowfall areas it is very important to select an installation
site where the snow will NOT affect the unit. If lateral snowfall is
possible, make sure that the heat exchanger coil is NOT affected by
the snow. If necessary, install a snow cover or shed and a pedestal.
4.2 Mounting the outdoor unit
4.2.1 To provide the installation structure
Use a vibration-proof rubber (field supply) in cases where vibrations
may be transmitted to the building.
Prepare 4 sets of M8 or M10 anchor bolts, nuts and washers (field
supply).
20 mm

Table of Contents

Other manuals for Daikin RXTP25N2V1B8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin RXTP25N2V1B8 and is the answer not in the manual?

Daikin RXTP25N2V1B8 Specifications

General IconGeneral
BrandDaikin
ModelRXTP25N2V1B8
CategoryAir Conditioner
LanguageEnglish

Related product manuals