SiEN04-306D Indoor Unit
Removal Procedure 155
1.4 Removal of the Electrical Box / PCB / Swing Motor
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1. Remove the front grille.
Parts layout
2. Remove the drip proof
plate.
1
Loosen the screw.
3. Disconnect the indoor
heat exchanger thermistor
and the earth.
Mind that not to lose the clip
for the thermistor.
Drip proof plate
(R2771)
Indoor heat exchanger thermistor
Earth
(R2772)