For FHYC71K Si-71A
134 Removal Procedure
4 Remove the 14 screws on
the two remaining sides
and open the covers.
Reassembly
Check to make sure the heat
insulation is installed in the air outlet
section as shown below. (Improper
heat insulation installation results in
condensation of water.)
Step Procedure Points
Panel body
Heat insulation material
Seal material
(SR026)