EDUS121131 Capacity Tables
SUPER MULTI NX 2/3/4MXS-G/J Series Heat Pump 85
1
FDXS09L +
FDXS09L +
FDXS09L
68.0 24.08 1.94 25.16 1.97 26.24 2.01 26.78 2.03 28.41 2.09 29.49 2.13
77.0 22.98 2.05 24.06 2.09 25.15 2.13 25.69 2.15 27.31 2.21 28.40 2.24
86.0 21.89 2.18 22.97 2.22 24.05 2.26 24.59 2.28 26.22 2.33 27.30 2.37
89.6 21.45 2.23 22.53 2.27 23.62 2.31 24.16 2.33 25.78 2.39 26.86 2.43
95.0 20.79 2.32 21.88 2.35 22.96 2.39
23.50 2.41 25.12 2.47 26.21 2.51
104.0 19.70 2.46 20.78 2.50 21.86 2.54 22.40 2.56 23.80 2.56 24.70 2.56
109.4 16.04 1.77 16.73 1.77 17.39 1.77 17.72 1.77 18.68 1.77 19.31 1.77
114.8 10.18 0.98 10.56 0.98 10.93 0.98 11.11 0.98 11.64 0.98 11.98 0.98
CTXS09H +
CTXS09H +
CTXS12H
68.0 25.61 1.66 26.76 1.70 27.92 1.73 28.49 1.75 30.22 1.79 31.37 1.83
77.0 24.45 1.76 25.60 1.80 26.75 1.83 27.33 1.85 29.06 1.89 30.21 1.93
86.0 23.28 1.87 24.44 1.90 25.59 1.94 26.16 1.95 27.89 2.00 29.04 2.04
89.6 22.82 1.92 23.97 1.95 25.12 1.98 25.70 2.00 27.43 2.05 28.58 2.08
95.0 22.12 1.99 23.27 2.02 24.42 2.06
25.00 2.07 26.73 2.12 27.88 2.15
104.0 20.96 2.12 22.11 2.15 23.26 2.18 23.84 2.20 25.56 2.25 26.72 2.28
109.4 17.88 1.77 18.68 1.77 19.45 1.77 19.83 1.77 20.94 1.77 21.66 1.77
114.8 11.06 0.98 11.49 0.98 11.92 0.98 12.13 0.98 12.74 0.98 13.14 0.98
CTXS09H +
CTXS09H +
FDXS12L
68.0 25.20 1.77 26.34 1.81 27.47 1.85 28.04 1.86 29.74 1.92 30.87 1.95
77.0 24.06 1.88 25.19 1.92 26.32 1.95 26.89 1.97 28.59 2.02 29.72 2.06
86.0 22.91 2.00 24.05 2.03 25.18 2.07 25.75 2.09 27.45 2.14 28.58 2.17
89.6 22.45 2.05 23.59 2.08 24.72 2.12 25.29 2.14 26.99 2.19 28.12 2.22
95.0 21.77 2.12 22.90 2.16 24.03 2.19
24.60 2.21 26.30 2.27 27.43 2.30
104.0 20.62 2.26 21.75 2.30 22.89 2.33 23.45 2.35 25.15 2.40 26.29 2.44
109.4 17.14 1.77 17.89 1.77 18.62 1.77 18.98 1.77 20.03 1.77 20.71 1.77
114.8 10.71 0.98 11.12 0.98 11.52 0.98 11.72 0.98 12.30 0.98 12.67 0.98
CTXS09H +
FDXS09L +
CTXS12H
68.0 25.20 1.77 26.34 1.81 27.47 1.85 28.04 1.86 29.74 1.92 30.87 1.95
77.0 24.06 1.88 25.19 1.92 26.32 1.95 26.89 1.97 28.59 2.02 29.72 2.06
86.0 22.91 2.00 24.05 2.03 25.18 2.07 25.75 2.09 27.45 2.14 28.58 2.17
89.6 22.45 2.05 23.59 2.08 24.72 2.12 25.29 2.14 26.99 2.19 28.12 2.22
95.0 21.77 2.12 22.90 2.16 24.03 2.19
24.60 2.21 26.30 2.27 27.43 2.30
104.0 20.62 2.26 21.75 2.30 22.89 2.33 23.45 2.35 25.15 2.40 26.29 2.44
109.4 17.14 1.77 17.89 1.77 18.62 1.77 18.98 1.77 20.03 1.77 20.71 1.77
114.8 10.71 0.98 11.12 0.98 11.52 0.98 11.72 0.98 12.30 0.98 12.67 0.98
CTXS09H +
FDXS09L +
FDXS12L
68.0 24.79 1.88 25.91 1.92 27.02 1.95 27.58 1.97 29.25 2.03 30.37 2.07
77.0 23.67 1.99 24.78 2.03 25.90 2.07 26.45 2.09 28.13 2.14 29.24 2.18
86.0 22.54 2.12 23.65 2.15 24.77 2.19 25.33 2.21 27.00 2.27 28.11 2.30
89.6 22.09 2.17 23.20 2.21 24.32 2.24 24.88 2.26 26.55 2.32 27.66 2.35
95.0 21.41 2.25 22.53 2.29 23.64 2.32
24.20 2.34 25.87 2.40 26.99 2.44
104.0 20.29 2.39 21.40 2.43 22.52 2.47 23.07 2.49 24.75 2.54 25.77 2.56
109.4 16.57 1.77 17.28 1.77 17.98 1.77 18.32 1.77 19.32 1.77 19.97 1.77
114.8 10.44 0.98 10.83 0.98 11.22 0.98 11.40 0.98 11.96 0.98 12.32 0.98
FDXS09L +
FDXS09L +
CTXS12H
68.0 24.79 1.88 25.91 1.92 27.02 1.95 27.58 1.97 29.25 2.03 30.37 2.07
77.0 23.67 1.99 24.78 2.03 25.90 2.07 26.45 2.09 28.13 2.14 29.24 2.18
86.0 22.54 2.12 23.65 2.15 24.77 2.19 25.33 2.21 27.00 2.27 28.11 2.30
89.6 22.09 2.17 23.20 2.21 24.32 2.24 24.88 2.26 26.55 2.32 27.66 2.35
95.0 21.41 2.25 22.53 2.29 23.64 2.32
24.20 2.34 25.87 2.40 26.99 2.44
104.0 20.29 2.39 21.40 2.43 22.52 2.47 23.07 2.49 24.75 2.54 25.77 2.56
109.4 16.57 1.77 17.28 1.77 17.98 1.77 18.32 1.77 19.32 1.77 19.97 1.77
114.8 10.44 0.98 10.83 0.98 11.22 0.98 11.40 0.98 11.96 0.98 12.32 0.98
Combination
(Capacity)
Outdoor air
temp.
EDB (°F)
Indoor air temp. EWB (°F)
57.2 60.8 64.4 67.0 71.6 75.2
TC PI TC PI TC PI TC PI TC PI TC PI
kBtu/h kW kBtu/h kW kBtu/h kW kBtu/h kW kBtu/h kW kBtu/h kW