What causes overload relays or circuit breakers to open on a Daikin Chiller?
T
Tara GoodmanAug 14, 2025
If the motor overload relays or circuit breakers are open in your Daikin Chiller, it could be due to a voltage imbalance or a voltage that is out of range, which requires correcting the power supply. Defective or grounded wiring in the motor necessitates replacing the compressor. Loose power wiring or burnt contactors require checking all connections, tightening them, and replacing the contactors if needed. High condenser temperature can also cause this issue, so refer to the corrective steps for high discharge pressure.
P
pcruzAug 21, 2025
Why is the discharge pressure high in my Daikin Chiller?
A
amandazimmermanAug 21, 2025
High discharge pressure in your Daikin Chiller can stem from several issues. Noncondensables in the system require extraction using approved procedures, or you may need to replace the charge. An overcharged circuit needs excess refrigerant removed, and liquid subcooling should be checked. Ensure the optional discharge shutoff valve is open. Incorrect condenser fan control wiring needs correction. If the fan isn't running, check the electrical circuit and fan motor. A dirty condenser coil requires cleaning, and air recirculation needs to be corrected.
O
ogonzalezAug 25, 2025
How to fix a noisy or vibrating Daikin Chiller compressor?
D
David SmithAug 25, 2025
If your Daikin Chiller's compressor is noisy or vibrating, several factors could be at play. Low lift or an inverted start might require control adjustments or condenser fan VFDs. Ensure the compressor isn't running in reverse by checking the unit and compressor for correct phasing. Improper piping or support on the suction or discharge lines may necessitate relocating, adding, or removing hangers. Worn compressor isolator bushings should be replaced. In cases of compressor mechanical failure, replacement is necessary.
M
Megan VelasquezSep 3, 2025
Why won't my Daikin Trailblazer AGZ030-101E Chiller compressor stage up?
R
Richard GeorgeSep 4, 2025
If your Daikin Chiller compressor will not stage up, it could be due to a defective capacity control, which would need replacing. Another cause may be a faulty sensor or wiring, which also requires replacement. It's also possible that the stages are not set for the specific application, in which case you should adjust the controller setting accordingly.
D
dalegentrySep 7, 2025
What causes short compressor staging intervals in Daikin Chiller?
X
xbentonSep 7, 2025
If the compressor staging intervals are too short on your Daikin Chiller, the control band may not be set properly, requiring adjustment of the controller settings for the application. A faulty water temperature sensor should be replaced. Insufficient water flow requires correction. Rapid temperature or flow swings necessitate stabilizing the load. Oversized equipment may require evaluating the equipment selection. If the chiller is enabled with no load, evaluate the BAS sequence and settings. For light loads, evaluate the need for HGBP or thermal inertia.
R
Ryan GordonSep 10, 2025
What does it mean if my Daikin Chiller's compressor thermal protection switch is open?
L
Lauren StokesSep 12, 2025
If the compressor thermal protection switch opens on your Daikin Chiller, it could be due to operating beyond design conditions, which requires correcting the conditions to stay within allowable limits. Ensure the discharge valve is open. Short cycling can also cause this, so stabilize the load or correct control settings for the application. Check and correct any voltage range or imbalance. High superheat requires adjustment to correct superheat. In some cases, compressor mechanical failure may be the cause, necessitating compressor replacement.