Servi ce
Manual
Heat Recovery 60 Hz
REYQ-AATJA/B, 208/230 V
REYQ-AAYDA/B, 460 V
SiUS372201EB

Table of Contents

Questions and Answers:

Daikin VRV EMERION REYQ-AATJA Specifications

General IconGeneral
SeriesVRV EMERION
ModelREYQ-AATJA
RefrigerantR410A
Maximum Number of Indoor Units16
Power Supply380-415V, 3-phase, 50Hz
Operating Temperature Range (Cooling)-5°C to 46°C DB
Operating Temperature Range (Heating)-20°C to 15.5°C
Sound Pressure Level (Outdoor Unit)58 dB(A)

Summary

Introduction

Safety Cautions

Read safety cautions before repair work. Observe all safety caution items described.

Icons Used

Explanation of icons used in the manual to attract reader attention to specific information.

Revision History

List of revisions, including month/year, version, and revised contents.

Part 1 General Information

Model Names

Lists model names for outdoor units, branch selector units, indoor units, and air treatment equipment.

External Appearance

Provides visual representations of single and double outdoor units, branch selector units, and various indoor units.

Combination of Outdoor Units

Details combinations of outdoor units based on system capacity (Ton, HP) and module.

Capacity Range

Defines connection ratios and maximum connection ratios for various indoor unit types.

Specifications

Provides detailed specifications for REYQ-AATJA/AATJB and REYQ-AAYDA/AAYDB models.

Part 2 Refrigerant Circuit

Refrigerant Circuit (Piping Diagrams)

Presents refrigerant circuit diagrams for outdoor units, branch selector units, indoor units, and outdoor-air processing units.

Functional Parts Layout

Details the functional parts layout for various REYQ models, including plane and front views.

Refrigerant Flow for Each Operation Mode

Illustrates refrigerant flow during cooling, heating, defrost, and oil return operations.

Part 3 Remote Controller

Applicable Models

Lists applicable models for wired and wireless remote controllers, specifying series and model names.

Names and Functions

Details the names and functions of BRC1E73, BRC1H71W, and wireless remote controllers.

Main/Sub Setting

Explains the Main/Sub setting for indoor units when controlled by two remote controllers.

Address Setting for Wireless Remote Controller

Provides instructions for performing address setting for the receiver and wireless remote controller.

Centralized Control Group No. Setting

Details how to set group numbers for centralized remote control using the operating remote controller.

Service Settings Menu, Maintenance Menu

Outlines the Service Settings and Maintenance Menus accessible via the remote controller.

Administrator Menu, Installer Menu

Provides details on accessing the Administrator and Installer menus for specific settings.

Part 4 Functions and Control

Operation Flowchart

Illustrates the overall operation flowchart of the system, including stop, standby, startup, basic, protection, special, and other controls.

Stop Control

Details stop conditions such as stop due to error, system in stop control, and sub unit stops.

Standby Control

Explains restart standby and crankcase heater control during standby periods.

Startup Control

Describes controls for equalizing pressure and managing startup in cooling and heating.

Basic Control

Covers normal control, compressor PI control, compressor step control, and electronic expansion valve PI control.

Protection Control

Details various protection controls including high pressure, low pressure, discharge pipe, and inverter protection.

Special Control

Explains special controls like pump down, oil return, defrost, outdoor unit rotation, and mode switching.

Other Control

Covers backup operation, demand operation, and heating operation prohibition.

Outline of Control (Indoor Unit)

Provides an overview of indoor unit control, including operation flowcharts and temperature settings.

Part 5 Field Settings and Test Operation

Field Settings for Indoor Unit

Details field settings for indoor units, including remote controller settings, applicable settings, and gas furnace setup.

Field Setting from Outdoor Unit

Covers DIP switch settings, accessing PCB buttons, operating switches, PC configurator connection, and monitoring functions.

Field Settings for Branch Selector Unit

Provides instructions for setting DIP switches for single and multi branch selector units.

Test Operation

Outlines checks before test operation, checkpoints, and gas furnace test operation procedures.

Part 6 Service Diagnosis

Symptom-based Troubleshooting

Troubleshooting guide based on observed symptoms like system not starting, immediate stops, or poor cooling/heating.

Error Code via Remote Controller

Explains how to check and interpret error codes displayed on the remote controller for diagnosis.

Troubleshooting by Error Code

Provides detailed troubleshooting steps for various error codes related to indoor, outdoor, and branch selector units.

Check

Outlines various checks for system components like high pressure, low pressure, power transistors, and wiring.

Part 7 Appendix

Wiring Diagrams

Provides detailed wiring diagrams for outdoor units, branch selector units, indoor units, and air treatment equipment.

Electrical Component Box Removal

Details the procedure for removing the electrical component box from the unit, including screw locations.