REYQ8-48PY1B
R-410A Heat Recovery 50Hz
SiBE37 - 701

Table of Contents

Questions and Answers

  • C
    Cassie RogersAug 5, 2025
    Why is my Daikin VRV III REYQ16PY1B not cooling or heating air well?
    • B
      Brenda AllenAug 5, 2025
      There are several reasons why your Daikin Heating System might not be cooling or heating air effectively. Check for the following: * Blocked air inlet or outlet of either the indoor or outdoor unit. If blocked, remove the obstacle(s). * Clogged air filter(s). If clogged, clean the air filter(s). * Enclosed outdoor unit(s). If enclosed, remove the enclosure. * Improper temperature setting. If set improperly, adjust the temperature to the correct degree. * Airflow rate set to 'LOW'. If set to low, adjust it to a proper airflow rate. * Improper direction of air diffusion. If set improperly, adjust it to a proper direction. * Open window(s) or door(s). If open, shut them tightly. * Direct sunlight. If the unit receives direct sunlight, hang curtains or shades on the windows.
  • W
    William StokesAug 9, 2025
    How to fix a Daikin VRV III REYQ16PY1B that does not start?
    • K
      Keith PerezAug 9, 2025
      If your Daikin Heating System fails to start, consider the following potential causes and solutions: * **Blown fuse(s):** Turn off the power supply and replace the fuse(s). * **Tripped breaker(s):** If the breaker knob is in the OFF position, turn the power supply ON. However, if the circuit breaker knob is in the tripped position, do not turn the power supply ON. * **Power failure:** After the power is restored, restart the system.
  • A
    allen79Aug 13, 2025
    What to do if my Daikin VRV III REYQ16PY1B starts then stops immediately?
    • K
      Kimberly HunterAug 14, 2025
      If your Daikin Heating System starts but stops immediately, the issue might be due to: * A blocked air inlet or outlet of the indoor or outdoor unit. Make sure to remove any obstacles. * Clogged air filters. Ensure you clean the air filters.
  • A
    Alexander MaloneAug 18, 2025
    Why does my Daikin Heating System make intermittent stops?
    • X
      xhendersonAug 18, 2025
      If your Daikin Heating System stops intermittently, and the remote controller displays malfunction codes 'U4' and 'U5' before restarting after a few minutes, the cause might be electrical noises. Try to remove the sources of electrical noises. After these causes are removed, the system will automatically restart operation.
  • S
    Steven AndersonAug 22, 2025
    Why is a white mist coming out of my Daikin VRV III REYQ16PY1B?
    • P
      Peggy MurphyAug 22, 2025
      A white mist coming from your Daikin Heating System can be due to a few reasons: * During cooling operation, the ambient humidity is high, especially if the indoor unit is in a place with oil or dust. Clean the inside of the indoor unit. * Immediately after cooling operation stops, the ambient temperature and humidity are low. This is normal operation. * After defrosting, the system switches to heating operation. This is also normal operation.
  • J
    Jeffrey WashingtonAug 27, 2025
    How to enable COOL-HEAT selection on my Daikin VRV III REYQ16PY1B?
    • A
      Anthony EllisAug 27, 2025
      If the COOL-HEAT selection is disabled on your Daikin Heating System, it might be due to centralized control. If the remote controller displays 'UNDER CENTRALIZED CONTROL', use a remote controller with the option to select cooling operation. If a COOL-HEAT selection remote controller is provided, use it to select cool or heat.
  • S
    Shane MartinAug 31, 2025
    Why does my Daikin VRV III REYQ16PY1B emit odors?
    • N
      Nicole OdonnellAug 31, 2025
      If your Daikin Heating System emits odors during operation, the inside of the indoor unit should be cleaned.

Summary

Part 1 General Information

1.1 Safety Cautions

Essential safety guidelines and warnings for handling the equipment and performing repairs.

Part 4 Function

4. Protection Control

Control mechanisms to protect the system from various fault conditions.

4.1 High Pressure Protection Control

Control to prevent tripping due to abnormal high pressure and protect compressors.

4.2 Low Pressure Protection Control

Control to protect compressors from transient decreases in low pressure.

Part 5 Test Operation

1.2.1 Check Work Prior to Turn Power Supply On

Essential checks before applying power to the system.

Part 6 Troubleshooting

1. Symptom-based Troubleshooting

Troubleshooting guide based on observable symptoms.

2. Troubleshooting by Remote Controller

Troubleshooting procedures using the remote controller functions.

3. Troubleshooting by Indication on the Remote Controller

Troubleshooting guide based on error codes displayed on the remote controller.

3.1 “A0” Indoor Unit: Error of External Protection Device

Troubleshooting steps for "A0" error code related to external protection devices.

3.13 “E1” Outdoor Unit: PC Board Defect

Troubleshooting steps for "E1" error code indicating a defective outdoor unit PC board.

3.14 “E3” Outdoor Unit: Actuation of High Pressure Switch

Troubleshooting steps for "E3" error code related to high pressure switch actuation.

3.15 “E4” Outdoor Unit: Actuation of Low Pressure Sensor

Troubleshooting steps for "E4" error code related to low pressure sensor actuation.

Part 8 Precautions for New Refrigerant (R-410 A)