REYQ8-48PY1B
R-410A Heat Recovery 50Hz
SiBE37 - 701

Table of Contents

Questions and Answers

  • T
    Tracy KennedyAug 1, 2025
    Why is my Daikin VRV III REYQ8PY1B not cooling or heating air well?
    • J
      Jeremy DuncanAug 1, 2025
      There are several reasons why your Daikin Heating System might not be cooling or heating air effectively. Check for the following: * Blocked air inlet or outlet of either the indoor or outdoor unit. If blocked, remove the obstacle(s). * Clogged air filter(s). If clogged, clean the air filter(s). * Enclosed outdoor unit(s). If enclosed, remove the enclosure. * Improper temperature setting. If set improperly, adjust the temperature to the correct degree. * Airflow rate set to 'LOW'. If set to low, adjust it to a proper airflow rate. * Improper direction of air diffusion. If set improperly, adjust it to a proper direction. * Open window(s) or door(s). If open, shut them tightly. * Direct sunlight. If the unit receives direct sunlight, hang curtains or shades on the windows.
  • T
    terrancewareAug 5, 2025
    How to fix a Daikin VRV III REYQ8PY1B Heating System that does not start?
    • E
      Erica TorresAug 5, 2025
      If your Daikin Heating System fails to start, consider the following potential causes and solutions: * **Blown fuse(s):** Turn off the power supply and replace the fuse(s). * **Tripped breaker(s):** If the breaker knob is in the OFF position, turn the power supply ON. However, if the circuit breaker knob is in the tripped position, do not turn the power supply ON. * **Power failure:** After the power is restored, restart the system.
  • J
    John RomeroAug 10, 2025
    What to do if my Daikin VRV III REYQ8PY1B starts then stops immediately?
    • A
      Andrew MurphyAug 10, 2025
      If your Daikin Heating System starts but stops immediately, the issue might be due to: * A blocked air inlet or outlet of the indoor or outdoor unit. Make sure to remove any obstacles. * Clogged air filters. Ensure you clean the air filters.
  • S
    srobertsAug 14, 2025
    Why does my Daikin VRV III REYQ8PY1B make intermittent stops?
    • Z
      Zachary WhiteAug 14, 2025
      If your Daikin Heating System stops intermittently, and the remote controller displays malfunction codes 'U4' and 'U5' before restarting after a few minutes, the cause might be electrical noises. Try to remove the sources of electrical noises. After these causes are removed, the system will automatically restart operation.
  • V
    vjohnstonAug 18, 2025
    Why is a white mist coming out of my Daikin Heating System?
    • E
      Elizabeth EnglishAug 18, 2025
      A white mist coming from your Daikin Heating System can be due to a few reasons: * During cooling operation, the ambient humidity is high, especially if the indoor unit is in a place with oil or dust. Clean the inside of the indoor unit. * Immediately after cooling operation stops, the ambient temperature and humidity are low. This is normal operation. * After defrosting, the system switches to heating operation. This is also normal operation.
  • M
    Miranda KelleyAug 22, 2025
    How to enable COOL-HEAT selection on my Daikin VRV III REYQ8PY1B Heating System?
    • A
      Amber BentonAug 23, 2025
      If the COOL-HEAT selection is disabled on your Daikin Heating System, it might be due to centralized control. If the remote controller displays 'UNDER CENTRALIZED CONTROL', use a remote controller with the option to select cooling operation. If a COOL-HEAT selection remote controller is provided, use it to select cool or heat.
  • J
    John GrantAug 27, 2025
    Why does my Daikin Heating System emit odors?
    • R
      Ronald MayoAug 27, 2025
      If your Daikin Heating System emits odors during operation, the inside of the indoor unit should be cleaned.

Summary

Part 1 General Information

Part 4 Function

2. Basic Control

Explains basic controls like normal operation, compressor PI control, and fan control.

3. Special Control

Details special controls such as startup, oil return, defrost, and pump-down operations.

4. Protection Control

Outlines various protection controls including high pressure, low pressure, and inverter protections.

6. Outline of Control (Indoor Unit)

Details indoor unit controls including operation flow charts, thermostat, drain pump, and freeze prevention.

Part 5 Test Operation

3. Field Setting

Explains field setting procedures for remote controllers and outdoor units, including dip switch settings.

Part 6 Troubleshooting

1. Symptom-based Troubleshooting

Lists common symptoms, their supposed causes, and corresponding countermeasures.

2. Troubleshooting by Remote Controller

Details methods for troubleshooting using remote controller features like inspection, self-diagnosis, and service modes.

3. Troubleshooting by Indication on the Remote Controller

Provides troubleshooting steps for various error codes displayed on the remote controller.

Part 8 Precautions for New Refrigerant (R-410 A)

1.2 Refrigerant Cylinders

Discusses cylinder specifications, handling, and storage precautions for R-410A.

Daikin VRV III REYQ8PY1B Specifications

General IconGeneral
ModelVRV III REYQ8PY1B
CategoryHeating System
Cooling Capacity (kW)22.4
Heating Capacity (kW)25.0
RefrigerantR410A
Energy Efficiency ClassA
Power Supply380-415V / 50Hz / 3 Phase
Indoor Unit CompatibilityCompatible with multiple indoor units
Indoor Unit Dimensions (HxWxD)N/A (Outdoor unit only)
Indoor Unit WeightN/A (Outdoor unit only)