Questions and Answers

  • P
    phillip79Aug 5, 2025
    Why is my Daikin VRV III REYQ14PY1B Heating System not cooling or heating air well?
    • T
      Taylor OliverAug 5, 2025
      There are several reasons why your Daikin Heating System might not be cooling or heating air effectively. Check for the following: * Blocked air inlet or outlet of either the indoor or outdoor unit. If blocked, remove the obstacle(s). * Clogged air filter(s). If clogged, clean the air filter(s). * Enclosed outdoor unit(s). If enclosed, remove the enclosure. * Improper temperature setting. If set improperly, adjust the temperature to the correct degree. * Airflow rate set to 'LOW'. If set to low, adjust it to a proper airflow rate. * Improper direction of air diffusion. If set improperly, adjust it to a proper direction. * Open window(s) or door(s). If open, shut them tightly. * Direct sunlight. If the unit receives direct sunlight, hang curtains or shades on the windows.
  • P
    Phillip WalkerAug 9, 2025
    How to fix a Daikin Heating System that does not start?
    • R
      Robin McleanAug 10, 2025
      If your Daikin Heating System fails to start, consider the following potential causes and solutions: * **Blown fuse(s):** Turn off the power supply and replace the fuse(s). * **Tripped breaker(s):** If the breaker knob is in the OFF position, turn the power supply ON. However, if the circuit breaker knob is in the tripped position, do not turn the power supply ON. * **Power failure:** After the power is restored, restart the system.
  • C
    Carol GonzalesAug 13, 2025
    What to do if my Daikin VRV III REYQ14PY1B starts then stops immediately?
    • A
      Ann TuckerAug 14, 2025
      If your Daikin Heating System starts but stops immediately, the issue might be due to: * A blocked air inlet or outlet of the indoor or outdoor unit. Make sure to remove any obstacles. * Clogged air filters. Ensure you clean the air filters.
  • U
    urodriguezAug 18, 2025
    Why does my Daikin Heating System make intermittent stops?
    • N
      nguyentylerAug 18, 2025
      If your Daikin Heating System stops intermittently, and the remote controller displays malfunction codes 'U4' and 'U5' before restarting after a few minutes, the cause might be electrical noises. Try to remove the sources of electrical noises. After these causes are removed, the system will automatically restart operation.
  • A
    anthony05Aug 22, 2025
    Why is a white mist coming out of my Daikin Heating System?
    • O
      oadamsAug 22, 2025
      A white mist coming from your Daikin Heating System can be due to a few reasons: * During cooling operation, the ambient humidity is high, especially if the indoor unit is in a place with oil or dust. Clean the inside of the indoor unit. * Immediately after cooling operation stops, the ambient temperature and humidity are low. This is normal operation. * After defrosting, the system switches to heating operation. This is also normal operation.
  • J
    jacobpetersAug 27, 2025
    How to enable COOL-HEAT selection on my Daikin Heating System?
    • M
      Mark OrtizAug 27, 2025
      If the COOL-HEAT selection is disabled on your Daikin Heating System, it might be due to centralized control. If the remote controller displays 'UNDER CENTRALIZED CONTROL', use a remote controller with the option to select cooling operation. If a COOL-HEAT selection remote controller is provided, use it to select cool or heat.
  • S
    Steven HamiltonAug 30, 2025
    Why does my Daikin VRV III REYQ14PY1B emit odors?
    • W
      Whitney FischerAug 30, 2025
      If your Daikin Heating System emits odors during operation, the inside of the indoor unit should be cleaned.

Summary

Introduction

Safety Cautions

Provides essential safety information for repair and product handling, including warnings and cautions.

Specifications

Refrigerant Circuit

Function

Protection Control

Describes various protection mechanisms to prevent system damage.

Test Operation

Test Operation

Provides a step-by-step guide for initial testing and operational checks.

Field Setting

Details the process of configuring system settings via remote controllers and outdoor units.

Troubleshooting

Symptom-based Troubleshooting

Lists common symptoms, their supposed causes, and countermeasures.

Troubleshooting by Remote Controller

Guides on using remote controller functions for diagnosing issues.

Troubleshooting by Indication on the Remote Controller

Provides detailed steps for diagnosing malfunctions based on remote controller error codes.

Appendix

Method of Checking the Inverter’s Power Transistors and Diode Modules

Details procedures for checking inverter power transistors and diode modules.

Precautions for New Refrigerant (R-410 A)

Precautions for New Refrigerant (R-410 A)

Covers crucial safety information regarding R-410A refrigerant handling, properties, and storage.

Refrigerant Cylinders

Provides guidelines on handling and storing refrigerant cylinders, including safety laws.

Daikin VRV III REYQ14PY1B Specifications

General IconGeneral
SeriesVRV III
ModelREYQ14PY1B
CategoryHeating System
TypeHeat Pump
RefrigerantR410A
Operating Temperature (Cooling)-5 to 46 °C
Sound Pressure Level (Outdoor Unit)58 dB(A)
Cooling Capacity14 kW
Heating Capacity16 kW
Power Supply380-415V, 50Hz