EasyManua.ls Logo

Dalla Corte Mina - Page 39

Dalla Corte Mina
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
| 39
Alarm Cause Solution
Signal:
light is steady on,
is blinking and three
beeps are emitted.
Steam boiler heating is
locked*.
Heating boiler time-out
The steam boiler does not reach
the temperature of 40°C within
10 minutes of turning on
The temperature probe is out
of the range, shorted out
or interrupted
Switch off the machine
and then switch it back on
If the alarm persists, please
contact an authorized Technical
Service centre
Signal:
light is steady on,
o
is blinking
and three beeps are emitted.
Coffee pouring must be
stopped manually by pushing
the M knob.
Failure Flow-meter
This alarm is triggered when
the electronic control does not receive
impulses from the flow meter during
coffee extraction
Switch off the machine
and then switch it back on
If the alarm persists, please
contact an authorized Technical
Service centre
Signal:
light is steady on,
is blinking and three
beeps are emitted.
Auto-filling is locked.
Auto-fill Time-out
The auto-filling mechanism
cannot bring the boiler water back
to its working level within a pre-set
time
Switch off the machine
and then switch it back on
If the alarm persists, please
contact an authorized Technical
Service centre
* During this alarm, the brewing group is on and keeps working.

Related product manuals