Alarm Cause Effect
AL07
Unit temperature
probe interrupted
in short circuit
The alarm is enabled
if the boiler temperature
probe reads the minimum
range and is therefore
interrupted
The unit heating function is disabled;
the boiler continues working.
The alarm display is canceled by pres-
sing the encoder but the unit remains
inhibited until the next POWER ON
AL08
Unit
overtemperature
The alarm is enabled if the
boiler temperature probe
reads a temperature hi-
gher than 120°
The unit heating function is disabled; the
boiler continues working.
The alarm display is canceled by pressing
the encoder but the unit remains inhibi-
ted until the next POWER ON
Unit flow meter alarms
AL09
Flow meter Alarm
The alarm is enabled if at
least 100 pulses are not
counted in the first 5 sec
during brewing
Brewing is not interrupted but the Led of
the selected dose flashes. Alarm enabled
only on the 2 dosed selections. Alarm reset
by setting the lever to the stop position