86 |
Alarm Cause Effect
General alarms
AL13
Data loss
The alarm is
enabled when
Equadro and
Flash do not pass
the checksum
At this point Equadro is reset (except for the counters)
and the default data is reloaded. The screen display
of the alarm is canceled by pressing the encoder button
AL14
Hall
lever
effect
alarm
The alarm is
enabled when no
brewing lever hall
is detected for 5
seconds
With the alarm enabled you can test all the positions
of the lever to check the correct functioning of all the halls.
Reset the alarm by pressing the encoder button.
If the stop position sensor is not detected during the check,
the operation is switched from automatic to manual mode
(with warning to be confirmed by pressing the encoder
button) and the sensors 1-2 stop while the sensors 3-4
continue the brewing