EasyManua.ls Logo

damian LUCE X SNAC User Manual

Default Icon
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
X
INSTALLATION AND SERVICE
PROGRAMMING
This manual is for skilled service personnel only
DAMIAN S.R.L. - VIA RAGAZZI DEL „99 N°30 - 21053 CASTELLANZA (VA) - ITALY
Rev. M - 01 Vers. Software 1.1a or follow.
Question and Answer IconNeed help?

Do you have a question about the damian LUCE X SNAC and is the answer not in the manual?

damian LUCE X SNAC Specifications

General IconGeneral
ModelLUCE X SNAC
CategoryVending Machines
ManufacturerDamian
TypeSnack vending machine
Power Supply230 V / 50 Hz
Dimensions1830 x 889 x 793 mm

Summary

Identification, Use and Technical Data

Legend of Symbols Used

Warnings and Cautions

Unpacking

Assembly of Base Plate

Installation

Power Supply

Power Cord Replacement

Using the Safety Switch

Installation of Payment Systems

Circuit Boards, Sliding Panel, Product Door

Legend

Explains the components and references shown in the circuit board diagram.

Overtemperature Control

Answers to Problems That Might Arise

Error Messages That Appear on the Display

Troubleshooting guide for error messages displayed on the vending machine.

FTCA Vending Sensor Errors

Troubleshooting for errors related to FTCA vending sensors.

"Push" Product Removal Door Errors

Troubleshooting for errors related to the product removal door.

Sliding Anti-Theft Panel Errors

Troubleshooting for errors related to the sliding anti-theft panel.

CL1 CPU Circuit Board Errors

Troubleshooting for errors related to the CPU circuit board.

CLP1 POT Circuit Board Errors

Troubleshooting for errors related to the CLP1 POT circuit board.

Keyb-SENS Error and Unforeseen Errors

Troubleshooting for keyboard sensor and general unforeseen errors.

Other Answers to Problems That Might Arise

Messages Relative to Motor Anomalies

Troubleshooting messages and solutions for motor anomalies.

Motor Anomaly Operational Issues

Guidance on specific motor anomaly messages and operational issues.

The Machine Does Not Reach the Required Temperature

Disassembly and Reassembly of the Refrigeration Unit

Fuses

Routine Maintenance and Lubrication

Safety Switch Check

Procedure to check the correct operation of the door safety switch.

Sliding Panel Check and Lubrication

Procedure for checking and lubricating the sliding panel.

Check/Cleaning of 'FTCA' Vending Sensors

Procedure to check and clean the FTCA vending sensors.

Check of Product Door Microswitches and Magnets

Procedure to check product door microswitches and magnets.

Check/Cleaning of the Refrigeration Unit Condenser

Procedure to check and clean the refrigeration unit condenser.

Environmental Protection

Warranty

Programming Method

To Enter into Programming

Instructions on how to access the programming mode.

To Choose the Parameter

Guide to selecting parameters within the programming menu.

To Change Programmed Value

Steps for modifying the value of a selected programming parameter.

To Exit Programming

Instructions for exiting the programming mode.

General Parameters

Message Language

Setting the display language for messages.

Operating Mode

Configuring the vending machine's operational mode.

Clock Setting

Procedure to set the current date and time.

Clock Visualisation Enable

Activating or deactivating the display of the current time.

Energy Saving Programming

Setting parameters for energy saving functions.

Save Mode - Activation Delay

Setting the delay for Save Mode activation.

Save Mode - Light Intensity

Setting the LED light intensity for Save Mode.

Night Mode - Timetable

Setting the start and end times for Night Mode.

Night Mode - Light Intensity

Setting the LED light intensity for Night Mode.

Night Mode - Internal Temperature Setting

Setting the internal temperature during Night Mode.

Refrigerator Operation

Visualizing and setting the refrigerator operating mode.

FTCA Parameters

Configuration for FTCA product detection sensors.

Enabling FTCA Vending Sensors

Activating the FTCA product detection sensors.

Maximum 3 FTCA Selections

Allowing additional selections after a missed sale.

Decimal Point

Setting the position of the decimal point for prices.

Code Mode

Allows reading the internal parameter software 'code mode'.

Visualisation of SW Versions Installed

Displaying the installed software versions.

Card Reinitialisation

Procedure to reinitialize the vending machine's CPU card.

Resetting Overtemperature Counters

Management of Selling Prices

'A' Bracket Selling Prices

Setting the primary selling prices for products.

Enabling of the 'B' Bracket Selling Prices

Activating management of the secondary price bracket.

'B' Bracket Selling Prices

Setting the secondary selling prices for products.

Price Association

Associating selling prices with product selections.

Display of the Selling Price

Enabling the display of product selling prices to customers.

Executive Payment System Parameters

Value of Each Step or Coin Scaling Factor

Setting the base coin value for price calculations.

MDB Payment System Parameters

Maximum Credit

Setting the maximum credit value accepted by the system.

Coin Return Parameters

Setting operating parameters for the coin return system.

Coin Minimum to Indicate No Change Available

Setting minimum coin threshold for 'no change' indication.

Coin Minimum in Tubes to Give Change

Setting minimum coin threshold for providing change.

Compulsory Sale

Enabling compulsory sale to prevent use as a coin changer.

Manual Emptying of the Coin Tubes

Enabling manual emptying of coin tubes.

MDB Sales Modes

Selecting the sales mode for MDB payment systems.

Coins and Tubes

Setting parameters for coins managed by the coin return system.

Coins Managed by the Coin Return System

Reading and enabling/disabling coins in coin return tubes.

Tokens Present

Reading and managing tokens in MDB payment system tubes.

Banknotes and Stacker

Reading and recognizing banknotes and tokens.

Banknotes Present

Reading and enabling/disabling banknotes.

Token

Enabling token recognition by an MDB banknote reader.

Cashless

Cashless N.1 (Price Bracket Association)

Associating price bracket A or B with Cashless system N.1.

Cashless N.2 (Price Bracket Association)

Associating price bracket A or B with Cashless system N.2.

RFID Parameters

RFID – Price Bracket

Selecting the price bracket for RFID payment system.

RFID - Machine Codes

Setting correct machine codes for RFID system operation.

Refrigerator Parameters

Internal Temperature Reading

Reading the internal temperature of the vending machine.

Internal Temperature Setting

Setting the internal temperature of the vending machine.

Night Mode Internal Temperature Setting

Setting internal temperature during Night Mode.

Refrigeration Unit Working Temperature Reading

Reading the working temperature of the refrigeration unit.

Safety Temperature

Setting the safety temperature for food product sales.

Overtemperature Time

Setting the time limit for exceeding safety temperature.

Restocking Time

Time added to overtemperature time after restocking.

Connected Probes

Reading the number of connected refrigeration unit control probes.

EVA-DTS Parameters

Password Code Reset (EVA-DTS)

Resetting security and passcode codes for EVA-DTS.

Audit Parameters

Partial Counter of Number of Vending Machine Sales

Reading total vending machine sales count since last reset.

Partial Counter of Value of Vending Machine Sales

Reading total value collected since last reset.

Counter of Number of Sales per Selection

Total sales count for each vending machine selection.

Counter of Number of Sales per Line (Sales Price)

Total sales count for each product price line.

General Total Number of Vending Machine Sales

Reading the general total number of vending machine sales.

General Total Value of Vending Machine Sales

Reading the general total amount collected.

Audit Data Reset

Resetting partial totals counted by the vending machine.

Diagnostics

Out of Order Motors

Identifying motors that have generated an Out of Order condition.

Manual Motor Test

Procedure for testing individual motors through a sales cycle.

Motor Verify

Function to perform a quick check of motor conditions.

Motor Self-Learning

Procedure to repeat the self-learning of vending machine motors.

Sliding Panel Test

Test for the sliding anti-theft panel operation.

"Push" Product Removal Door Test

Test for the 'Push' product removal door operation.

Vending Sensor Test (FTCA)

Test for the FTCA vending sensor circuit.

EC Declaration of Conformity

General Warranty Conditions

Technical Modification Reservation

Related product manuals