Page #27 background imageLoading...
Page #27 background image
Serie "LXS9"
Pagina A - 5
Rev. M - 01
> REFRIGERATOR OPERATION:
(Visualisation only, programmable by reinitialising the card)
To visualise the operating mode of the refrigeration unit.
[ Default: Self-learned ]
The three possible operating modes, programmable by reinitialising the card, are:
- Food & Snack, enables management of the safety temperature for the Food zone.
- Drink & Snack, disables management of the safety temperature for the Food zone.
- OFF, disables operation of the refrigeration unit.
> FTCA PARAMETERS:
The series LXS9 vending machines can have an infrared system installed on the sides of the pick up tray
for detecting actual passage of the product (Sale has occurred).
This infrared system comprises a pair of infrared LED barriers which, during normal operation, are
protected/hidden by the sliding anti-theft panel, which is closed.
At each sale the FTCA barriers check the actual passage of the product; if it is not detected (Missed Sale),
the vending machine maintains the credit and, if the “Enable + 3 step” mode is active, it attempts to make
the spiral turn again by about ¼ turn, repeating the operation 3 consecutive times. If these attempts also
fail (or if the 3 step function is not active), the vending machine still keeps the credit stored in memory and
allows a new selection to be made.
When this function is selected it will be possible to set the following parameters of the FTCA function.
» ENABLING FTCA VENDING SENSORS:
To activate operation of the vending sensors that check passage of the product.
Settable values:
0) Disabled „, FTCA deactivated;
1) Enable NoStep‟ FTCA activated;
2) Enable + 3Step‟ FTCA activated + 1/4 turn management.
[ Default: 2)Enable + 3Step ]
» MAXIMUM 3 FTCA SELECTIONS:
In the case of a missed sale, allows making up to a maximum of 3 other selections without losing the
credit. Settable values: Disabled‟ (OFF), „Enabled‟ (ON).
[ Default: Enabled ]
IMPORTANT: When this parameter is enabled, at the third consecutive sale of the same selection
without detecting the product drop, the motor is put out of order and the credit deducted.
> DECIMAL POINT:
Sets the position of the decimal point on the display; used to indicate prices with parts in cents; the value 1
corresponds to 1 decimal (0000.0). Settable values: 0 ÷ 3
[ Default: 2 ]
Programming
General param.
Refrig.operation
Current value
F
Programming
General param.
FTCA parameters
->->->
FTCA enabling
Current value
F
F
Programming
General param.
FTCA parameters
->->->
Max 3 FTCA Selec
Current value
F
F
Programming
General param.
Decimal point
Current value
F