EasyManua.ls Logo

Danby DWC040A3BSSDD - Troubleshooting; Power and Cooling Issues; Condensation and Alarm Issues

Danby DWC040A3BSSDD
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TROUBLESHOOTING
Danby Consumer Care: 1-800-263-2629
Hours of operation:
Monday to Thursday 8:30 am - 6:00 pm Eastern Standard Time
Friday 8:30 am - 4:00 pm Eastern Standard Time
Information in this manual is subject to change without notice.
PROBLEM POSSIBLE CAUSE
No power A fuse may be blown or the circuit breaker
tripped
Plug not fully inserted into the wall outlet
Internal temperature not cold enough
Appliance runs continuously
Alarm sounding and “HI” on the display panel
Door is not shut properly or opened excessively
Exhaust vent is obstructed
Recently added a large quantity of warm bottles
to the cabinet
Close proximity to heat source or direct sunlight
Ambient temperature or humidity is very high
Possible system leak, evaporator fan failure or
compressor failure
Condensation on the cabinet or door Door is not shut properly or opened excessively
Ambient temperature or humidity is very high
Alarm sounding and “LO” or “CL” on the display
panel
Ambient temperature is excessively low
• Sensor failure
Evaporator temperature is too low
8

Other manuals for Danby DWC040A3BSSDD

Related product manuals