PROBLEM POSSIBLE CAUSE
No power • A fuse may be blown or the circuit breaker
tripped
• Plug not fully inserted into the wall outlet
Internal temperature not cold enough
Appliance runs continuously
Alarm sounding and “HI” on the display panel
• Door is not shut properly or opened excessively
• Exhaust vent is obstructed
• Recently added a large quantity of warm bottles
to the cabinet
• Close proximity to heat source or direct sunlight
• Ambient temperature or humidity is very high
• Possible system leak, evaporator fan failure or
compressor failure
Condensation on the cabinet or door • Door is not shut properly or opened excessively
• Ambient temperature or humidity is very high
Alarm sounding and “LO” or “CL” on the display
panel
• Ambient temperature is excessively low
• Sensor failure
• Evaporator temperature is too low