Intelligent interpolative measurement
It is possible to make accurate measurements, even before the
system has reached its final resting angle after hoist adjustment.
The meter unit automatically displays the final resting angle within
three periods of oscillation. This reduces installation time, with no
need to wait until the system comes to rest after each angle
adjustment.
Temperature and humidity measurement
In addition, the sender unit incorporates a thermo- and hygrometer
(sensor) to derive the actual onsite temperature and humidity.
Note: The sensor is calibrated by factory default and requires
no re-calibration by the user.
The thermometer covers a range from 0 to 40 °C (32 to 104 °F)
with an accuracy of ± 2 °C (± 35.6 °F) while the hygrometer
covers the range of 10 to 100 % (relative humidity) with an
accuracy of ± 5 %.
The corresponding values are displayed on the «Home» screen of
the meter unit or, when integrated into the d&b Remote network,
the values can be read out within R1.