EasyManua.ls Logo

Danfoss CS2

Danfoss CS2
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Danfoss Heating
15
If the thermostat CET2000B-RF and receiver RX1-S have been
supplied together in a combined pack, the units have been
paired in the factory and no commissioning is required. If the
thermostat and receiver have been supplied separately follow
the steps below to pair the devices.
Step 1 RX1-S - Ensure RX1-S is wired in accordance with
instructions on page 8.
Step 2 CET2000B-RF - Insert 2xAA alkaline batteries. If the
CET2000B-RF is not already paired to the RX1-S it will enter its
learning mode shown by the ashing aerial icon.
Step 3 RX1-S - Press and hold down both the PROG and CH
buttons. The PROG LED will light for 1 second when it has
paired with the CET2000B-RF. Release buttons
A steady aerial icon on CET2000B-RF conrms that the devices
are now paired and ready for control of your domestic hot water
system.