Do you have a question about the Danfoss CET2000B-RF and is the answer not in the manual?
Power Supply | 2 x AA batteries |
---|---|
Temperature Range | 5°C to 30°C |
Display | LCD |
Temperature Control Accuracy | ±0.5°C |
Communication Protocol | RF |
Mounting | Wall-mounted |
Compatibility | Danfoss RA, RAV, and RAVL valves |
Mount sensor on cylinder wall at half height, ensuring clean surface.
Connect 2-core cable to sensor for interconnection with thermostat setting unit.
Apply paste and clamp sensor to cylinder wall, using spacer for thick insulation.
Mount wallplate next to cylinder and connect sensor cable to terminals 1 & 2.
Mount the thermostat setting unit onto the wallplate using provided diagrams.
Wiring diagram showing connections between CET2000B-RF and CS2 sensor with cable specification.
Step-by-step diagrams and wiring instructions for the RX1-S receiver unit installation.
Diagrams illustrating how to mount the CET2000B-RF thermostat onto its wallplate.
Wiring diagram for a hard-wired system with a 3-port mid-position valve.
Wiring diagram for wireless control using two 2-port valves and two RX1-S receivers.
Wiring diagram for hard-wired system with wireless control and two 2-port valves.
Wiring diagram for wireless control with two RX1-S receivers and a 3-port mid-position valve.
Explanation of the key lock feature, how to set it using DIL switches, and its purpose.
Steps to pair the thermostat and receiver units if they were not pre-paired at the factory.