Danfoss EKC 302D User Manual

Danfoss EKC 302D
12 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
RI8KX753 09-2016
084R9986
INSTRUCTIONS
EKC 202D / EKC 302D
084R9986
Data communication
Type:
Pt 1000 (1000 Ω /0°C ) /
Ptc 1000 Type
NTC-M2020 (5000 Ω / 25°C)
( o06)
Koordineret afrimning
Coordinated defrost
t
amb
= 0 - +55°C
230 V a.c.
50/60 Hz
2.5 VA
10 V < U < 256 V
LON RS485:
MOD-bus
EKC 202D EKC 302D
LON RS485
EKC 302D
EKC 202D
IP 20
IEC60730
EKC 202D
DO1 8 (6) A & (5 FLA, 30 LRA)
DO2 8 (6) A & (5 FLA, 30 LRA)
DO3 6 (3) A & (3 FLA, 18 LRA)
DO4** 4 (1) A, Min. 100 mA**
EKC 302D
DO1
10 (6) A & (5 FLA, 30 LRA) 1)
16 (8) A & (10 FLA, 60 LRA) 2)
DO2
6 (3) A & (3 FLA, 18 LRA) 1)
10 (6) A & (5 FLA, 30 LRA) 2)
DO3
6 (3) A & (3 FLA, 18 LRA) 1)
10 (6) A & (5 FLA, 30 LRA) 2)
DO4** 4 (1)A Min. 100 mA**
* EKC 202D: DO1 and DO2 are 16 A relays. DO3 and DO4 are 8 A relays. Above
max. load must be kept.
EKC 302D: DO1 is 20 A relay. DO2 and DO3 are 16 A relays. DO4 is a 10 A
relay. The max. load listed above must be observed when connecting without zero-
crossing control. When connecting with zero-crossing control, the load must be
increased to the value indicated by 2)
** Gold plating ensures make function with small contact loads
1) With external relay (c70=ON) (zero-crossing control disabled)
2) Without external relay (c70=OFF) (zero-crossing control enabled)
Question and Answer IconNeed help?

Do you have a question about the Danfoss EKC 302D and is the answer not in the manual?

Danfoss EKC 302D Specifications

General IconGeneral
Analogue inputs2
TypeController
Input Voltage24 V AC/DC
Temperature Range-10°C to +50°C
Supply voltage24 V AC/DC

Summary

Product Overview and Specifications

Electrical and Environmental Ratings

Details electrical specifications (voltage, frequency, VA) and IP ratings for EKC 202D and EKC 302D controllers.

Output Relay Specifications

Lists current and load ratings for digital outputs (DO1-DO4) on EKC 202D and EKC 302D models.

Communication Interfaces

Details data communication options including LON RS485 and MOD-bus for the controllers.

Wiring and Connection Diagrams

EKC 202D Connection Examples

Illustrates various wiring configurations for the EKC 202D controller.

EKC 302D Connection Examples

Illustrates various wiring configurations for the EKC 302D controller.

Parameter Configuration

Normal Operation Parameters

Covers parameters for temperature setpoint, differential, and sensor adjustments.

Alarm and Compressor Settings

Details parameters for temperature alarms, compressor ON/OFF times, and relay functions.

Defrost and Fan Control Parameters

Explains settings related to defrost methods, timing, and fan operation.

Miscellaneous and Clock Settings

Includes parameters for output delays, input functions, network address, and real-time clock.

Advanced Settings and Operation

Access Codes and Controller Settings

Details access codes, sensor type selection, and display settings for controller configuration.

Fault and Status Code Displays

Explains the meaning of fault codes and status codes displayed by the controller.

User Interface Navigation

Describes the function of buttons for setting parameters, temperature, and controlling defrost.

LED Indicator Functions

Explains the meaning of the LED indicators for refrigeration, defrost, and fan status.