EasyManua.ls Logo

Danfoss ICS 25

Danfoss ICS 25
8 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
© Danfoss A/S (AC-MCI/MWA), 2012-01 DKRCI.PI.HS0.A3.52 / 520H0953 1
11
M27H0202_1
3a
3b
Instruction
Servostyret ventil ICS 25 - 65
Servo Operated Valve ICS 25 - 65
Servoventil ICS 25 - 65
Vanne à servocommande ICS 25 - 65
027R9775
027R9775
1
2
3
4
5
6
Ventilhus størrelse
Valve body size
Ventil-gehäusegröße
Taille du corps de vanne
Nm ft lb
Pos.
Rep.
A
25 100 74
32 120 88
40 120 88
50 140 103
65 150 110
Pos.
Rep.
B
25
25 18
32
40
50
65
Pos.
Rep.
C
25
50 37
32
40
50
65
A
C
B
Installation
7
A
B
Question and Answer IconNeed help?

Do you have a question about the Danfoss ICS 25 and is the answer not in the manual?

Danfoss ICS 25 Specifications

General IconGeneral
ModelICS 25
ManufacturerDanfoss
CategoryIndustrial Equipment
SizeDN 25
RefrigerantsApplicable to all common non-flammable refrigerants including R717 and R744 (CO₂). Natural refrigerants compatible depending on sealing material.
Max. Working Pressure52 bar (754 psi)
Temperature Range-60°C to 120°C (-76°F to 248°F)
Media Temperature-60°C to 120°C (-76°F to 248°F)

Summary

Installation

Welding

Remove valve components before welding to prevent damage to O-rings and debris.

Assembly

Reassemble valve components after welding, checking O-rings and lubricating for insertion.

Tightening

Use a torque wrench to secure the top cover according to specified values.

Colours and Identification

Valves are Zinc-Chromated; identify by ID plate and protect surfaces.

Service

ICS valves are designed for straightforward dismantling for service purposes.

Maintenance

Do not open under pressure; relieve via manual spindle, adhering to local regulations.