S5 – Floor Sensor Limit
This allows the remote thermostat limit sensor to be set,
typical application is oor heating. If the temperature sensed
by the limit sensor exceeds the limit setting the output will
be turned o until the temperature has dropped by2°C.
Setting Any value between 20 – 50°C (factory setting
27°C)
S4 – External Sensor Type
This allows type of remote sensor input to be dened.
Setting 0 No remote sensor tted (factory setting)
Setting 1 Remote room sensor tted, internal sensor
disabled
Setting 2 Remote limit sensor tted, refer to option S5
Setting 3 Digital window switch, refer to option S6