6 Frost Protection Temperature and Reset
You can switch the thermostat OFF (Standby) by alternately pressing . In OFF (Standby) mode, thethermo-
stat is set to a Frost Protection temperature setting and will switch On only if the measured temperature falls
below this temperature (5 °C by default).
The frost protect icon and current temperature will be displayed.
At this point, if the button is pressed for 10 seconds Continuously then the thermostat will be reset.
7 Set Control Parameters
Press M button for 6 seconds to enter the parameter setting mode. Press M for parameter selection and set
the parameter range via < or >. Complete all adjustments.
To exit press upper part of setting ring or wait 20 secs for automatic exit.
The digits indicate the set value as follows:
No. Parameter settings Settings range Default
P02 Heat control mode
01: On/o load compensation
02: On/o standard
01
P04 Temperature limit high Between low (P05) and 35 °C 35 °C
P05 Temperature limit low Between 5 °C and high (P04) 5 °C
P06 Frost protect temperature Between 5 °C and 15 °C 5 °C
P07 Away mode temperature Between low (P05) and high (P04) 18 °C
P10 RF Pairing (RET2001RF only)
00: RF pairing mode o
01: RF pairing mode on
00
8 Error Messages
E1 Sensor failure
EE EEPROM failure
Lo Measured temperature below 0 °C
Hi Measured temperature above 50 °C
E3 RF Pairing failed
E4 RF Signal lost