Select a location away from drafts, direct sunlight, or heat-emitting appliances like televisions.
Disconnect power before removing the cover. Fix the base to a flush box, limiting the temperature range with springs.
Details switch function (SPDT), voltage (230V), frequency (50-60Hz), and current rating (10(4)A, 150mA min).
Critical note: Always connect the live (L) wire to terminal 0.
RMT models with parallel accelerator Rp offer lower differential when terminal 4 is connected as shown.
The RMT-230T model reduces temperature by 5K when the built-in resistance Rn is connected.