EasyManua.ls Logo

Danfoss TMM 070 - User Manual

Danfoss TMM 070
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
MAKING MODERN LIVING POSSIBLE
Service Manual
Transit Mixer Axial Piston Motor
Size 070/084/089
powersolutions.danfoss.com

Table of Contents

Questions and Answers

  • C
    Christopher ClarkAug 2, 2025
    What causes low motor output torque in Danfoss TMM 070 Engine?
    • J
      jennifer31Aug 2, 2025
      Low motor output torque in your Danfoss Engine can be caused by low system pressure at the motor, which reduces torque. Measure the system pressure at the motor to check this. Internal leakage can also reduce system pressure, so check for leakage in O-rings, gaskets, and other fittings, and repair or replace the leaky unit as required.
  • C
    Cynthia HenryAug 10, 2025
    How to fix noise or vibration in Danfoss TMM 070 Engine system?
    • A
      Anthony HudsonAug 10, 2025
      System noise or vibration in your Danfoss Engine can be caused by several factors. A low oil level can lead to cavitation, so start by filling the reservoir. Air in the system can decrease efficiency, causing excessive noise, foaming oil, and hot oil, so find and repair the location where air is entering the system, and check that the inlet line is not restricted and is the proper size. Cold oil may be too viscous, causing pump cavitation; allow the oil to warm up to its normal operating temperature with the engine at idle speed. A loose shaft coupling will cause excessive noise, so replace it. Finally, misaligned shafts can create noise, so ensure that the shafts are properly aligned.
  • A
    Andrew PerezAug 14, 2025
    What to do if Danfoss TMM 070 system will not operate in either direction?
    • L
      Lisa WuAug 14, 2025
      If your Danfoss Engine system won't operate in either direction, start by checking the hydraulic fluid level and fill the reservoir to the proper level if it's insufficient. Low system pressure might not provide enough power to move the load, so measure the system pressure and proceed to the next step. A defective high-pressure relief valve can also cause low system pressure, so repair or replace the high-pressure relief valve.
  • E
    Erin ScottAug 19, 2025
    Why is my Danfoss Engine system response sluggish?
    • V
      Victor YatesAug 19, 2025
      A sluggish system response in your Danfoss Engine can arise from several causes. A low oil level can lead to a sluggish response, so begin by filling the reservoir. Incorrect pressure settings can affect system reaction time, so adjust or replace the high-pressure relief valves. Low engine speed reduces system performance, so adjust the engine speed. Air in the system can also produce a sluggish system response, so fill the tank to the proper level and cycle the system slowly for several minutes to remove air from the system.
  • B
    bryan26Aug 23, 2025
    Why is the motor output speed improper in my Danfoss TMM 070?
    • S
      stacyguzmanAug 23, 2025
      An improper motor output speed in your Danfoss Engine can be due to insufficient hydraulic fluid, which will reduce motor speed, so fill the oil to the proper level. Internal leakage can also reduce system pressure, so check for leaks in O-rings, gaskets, and other fittings, and repair the unit or replace it if it's leaky.
  • C
    Charles AguirreAug 27, 2025
    What to do if Danfoss TMM 070 transmission operates normally in one direction only?
    • J
      Justin MorrisAug 27, 2025
      If your Danfoss Engine transmission operates normally in only one direction, exchanging the high-pressure relief valves will show if the problem is related to the valve function. If the problem changes direction after the exchange, replace the valve that does not operate correctly.
  • M
    Megan DavisNov 5, 2025
    Why is my Danfoss TMM 070 system operating hot?
    • M
      Morgan WashingtonNov 5, 2025
      If your Danfoss Engine system is operating hot, it could be due to several reasons. Insufficient hydraulic fluid might not be meeting the system's cooling demands, so you should fill the reservoir to the proper level. The heat exchanger might not be sufficiently cooling the system; in this case, check the airflow and input air temperature for the heat exchanger, and then clean, repair, or replace it. Worn or contaminated system relief valves, or valve settings that are too low, can overwork the relief valves, so verify the settings of the high-pressure relief valves and replace them if necessary. Frequent or long-term operation over the system relief setting will create heat; measure the system pressure and reduce loads if the pressure is too high. Finally, leakage can reduce low side syst...

Summary

Introduction

Safety Precautions

General safety warnings for hydraulic systems, including fluid pressure and unintended movement.

Operation

High Pressure Relief Valve (HPRV)

Function of the HPRV in limiting system pressure and its role in the transmission loop.

Operating Parameters

System Pressure and Case Pressure

Limits and effects of system and case pressure on unit life.

Initial Start-up

Start-up Procedure

Step-by-step guide for starting up a new or re-installed pump/motor installation.

Minor Repair

Shaft Seal Replacement

Procedure for removing, inspecting, and reassembling the shaft seal on the motor.

High Pressure Relief Valves (HPRV)

Instructions for removing, inspecting, and reassembling HPRV components.

Torque Chart

Fasteners, Plugs, and Torques

Lists fasteners, wrench sizes, and specified torque values for various components.

Reference Literature

Further Available Literature

Lists related Danfoss publications and their order numbers for additional information.

Danfoss TMM 070 Specifications

General IconGeneral
BrandDanfoss
ModelTMM 070
CategoryEngine
LanguageEnglish