1007332 ISSUE 5
OWNER/INSTALLATION MANUAL
2�4 FEATURES
Stepless DC inverter compressor
EEV Technology (Electronic Equalisation Valve)
Quick reverse cycle defrosting wi 4-way valve
High-eciency twisted titanium heat exchanger
High pressure and low pressure protection
So start and wide voltage application
Stable inverter control system
2�5 OPERATING CONDITIONS AND RANGE
Air temperature operating range:
HPP-i 8, 12, 16: -5-43°C
HPP-iw 12, 16, 22: -10-43°C
Water temperature setting range:
Heating: 18°C-40°C
Cooling: 12°C-30°C
2�6 OPERATING MODES
The heat pump has two modes: Boost mode and
Whisper mode.
Mode Modes Characteristics
Boost mode
Heating capacity: 20% to 100% capacity
Intelligent optimization
Fastest heating
Whisper mode
Heating capacity: 20% to 80% capacity
Sound level: 3dB(A) lower an Boost mode