15
Software Parameters, cont'd
Parameter Description
Value Range
(units)
Factory
Default
Signal Input #2 (S2) Setup
35 S2 Input Configuration 1 – Disabled (Follower Mode)
2 – E-Stop When S2 High
3 – E-Stop When S2 Low
4 – Inhibit When S2 High
5 – Inhibit When S2 Low
6 – Jog When S2 High
7 – Jog When S2 Low
7
36 S2 Setpoint 1 – 9999 (Display Units) 100
37 S2 Pulses per Revolution 1 – 2048 (PPR) 1
User Input #1 (UIN1) Setup
40 UIN1 Input Configuration 1 – Disabled
2 – E-Stop When UIN1 High
3 – E-Stop When UIN1 Low
4 – Inhibit When UIN1 High
5 – Inhibit When UIN1 Low
6 – Jog When UIN1 High
7 – Jog When UIN1 Low
3
41 UIN1 Setpoint for Jog 1 – 9999 (Display Units) 100
Alarm Output #1 Configuration
50 Alarm Activation Conditions 0 – Always Off
1 – Always On
2 – Active when Above upper limit
3 – Active when Below lower limit
4 – Active inside Range
5 – Active outside Range
6 – Active when Target = 0
7 – Active when no Pickup Pulses
detected
8 – Active when at Max. Conduction
0
51 Output Style & Reset Mode 1 – Constant & Auto Reset
2 – Constant & Manual Reset
3 – Pulsed & Auto Reset
4 – Pulsed & Manual Reset
1
52 Reset Configuration 1 – No Sil., Reset on Key
2 – No Sil., Reset on S2 High
3 – No Sil., Reset on S2 Low
4 – Sil., Reset on Key
5 – Sil., Reset on S2 High
6 – Sil., Reset on S2 Low
1
53 Display Flash On Active Alarm 0 – Alarm Flash Disabled
1 – Alarm Flash Enabled
0
54 Pulse on Time 1 – 3600 (seconds) 1
55 Pulse off Time 1 – 3600 (seconds) 1
56 Pulse Count 0 – 9999 (pulses) 0
57 Lower Limit 0 – 9999 (display units) 0
58 Upper Limit 0 – 9999 (display units) 999
Parameter Memory Commands
95 Restore Settings to Factory Default 0 – Do Nothing & Exit
5 – Restore Factory Defaults
0
98 Save to User Default Area 0 – Do Nothing & Exit
5 – Save Setting
0
99 Restore from User Default Area 0 – Do Nothing & Exit
1 – Restore Settings
0
User
Settings