26
P1-1
P1-2
P1-3
P1-4
P1-5
P1-6
P1-7
P1-8
MD10P
MD3P
or
MD3E
*FUSE
MOTOR
P1-9
P1-10
P1-11
P1-12
* Size fuse according to unit and application. See
electrical specifications for maximums.
A+
COM
+5V
S1
S2
NO
C
NC
IN1
N
L
A-
}
AC Line Input 85-265VAC, 50-60 Hz
NOT USED
NOT USED
Dart PU-2E or
Equivalent
Encoder
black
white
red
NOT USED
NOT USED
Speed 1 Select
Speed 2 Select
NC
Wiring Diagram:
Parameter Configuration:
Synchronized Conveyor Controller with Jog Switch
Description:
A synchronized conveyor system comprised of two conveyors with no mechanical
linkage between them. The master conveyor is driven by a basic Dart analog DC motor
control. The slave or follower conveyor should follow the master's position with exacting
long-term accuracy. The slave conveyor should be able to be jogged into position when
the master is stopped at a rate of 350 RPM. The slave conveyor may be adjusted from
90.0% to 110.0% of the master conveyor rate using the user interface.
Parameter Value Notes
10 2 Time Mode Setting (MM:SS is a time-based unit)
20 390 Display minimum set to 6:30 (MM:SS)
For example: (6 minutes * 60 seconds-per-minute) + 30 seconds = 390 seconds
21 735 Display maximum set to 12:12 (MM:SS)
For example: (12 minutes * 60 seconds-per-minute) + 15 seconds = 735 seconds
30 400 Display should indicate 6:40 (MM:SS) when motor at Reference RPM, parameter 31
For example: (6 minutes * 60 seconds-per-minute) + 40 seconds = 400 seconds
31 1380 This is the RPM at which the Display Reference, parameter 30, should be displayed
32 1 Pulses per revolution of shaft encoder or pickup is 1 PPR
35 7 Set S2 input mode to jog when low
36 530 Set fixed process time during jog to 8:50 (MM:SS)
For example: (8 minutes * 60-seconds-per-minute) + 50 = 530 seconds