Loading...
14
Software Parameters
Parameter Description
Value Range
(units)
Factory
Default
0 Selecting this item exits to Running Mode n/a n/a
Read-Only Parameters
1 Model Number 10 – MD10P Unit
11 – MD3P Unit
13 – MD3E Unit
10, 11, or
13
2 Software Build 1 – 9999 n/a
3 Hardware Version 1 – 9999 n/a
4 Serial Number – Major (reserved) n/a n/a
5 Serial Number – Minor (reserved) n/a n/a
General Setup
10 Operating Mode 1 – Rate Mode
2 – Time Mode
3 – Follower Mode
1
11 Display Intensity 0 – 31 (Dim – Bright) 20
13 Decimal Point Position 0 – DP Disabled (XXXX)
1 – X.XXX
2 – XX.XX
3 – XXX.X
4 – XXXX.
0
14 Keypad Mode 1 – Linear, Constant Rate
2 – Non-linear, Accelerating Rate
2
15 Keypad Scroll Delay 0 – 30 (Fast – Slow) 10
16 S1 / S2 Input Edge & Prescaler Configuration 0 – S1 is Rising/1 S2 is Rising/1
1 – S1 is Falling/1 S2 is Rising/1
2 – S1 is Falling/4 S2 is Rising/1
3 – S1 is Falling/16 S2 is Rising/1
4 – S1 is Rising/1 S2 is Falling/1
5 – S1 is Falling/1 S2 is Falling/1
6 – S1 is Falling/4 S2 is Falling/1
7 – S1 is Falling/16 S2 is Falling/1
8 – S1 is Rising/1 S2 is Falling/4
9 – S1 is Falling/1 S2 is Falling/4
10 – S1 is Falling/4 S2 is Falling/4
11 – S1 is Falling/16 S2 is Falling/4
12 – S1 is Rising/1 S2 is Falling/16
13 – S1 is Falling/1 S2 is Falling/16
14 – S1 is Falling/4 S2 is Falling/16
15 – S1 is Falling/16 S2 is Falling/16
0
18 Power-up Mode 1 – Default to Zero Display
2 – Default to Power-up Value
3 – Default to Previous Running Val.
3
19 Power-up Value 0 – 9999 (Display Units) 0
Display & Control Loop Setup
20 Display Minimum 0 – 9998 (Display Units) 0
21 Display Maximum 1 – 9999 (Display Units) 2400
23 Accel Setting 1 – 9999 (Display Units) 2500
24 Decel Setting 1 – 9999 (Display Units) 2500
26 Proportional Gain 0 – 9999 (Not Unit-specific) 0
27 Integral Gain 1 – 9999 (Not Unit-specific) 5000
29 Pulse Accumulation Limit 2 – 5000 (Not Unit-specific) 15
Signal Input #1 (S1) Setup
30 S1 Display Reference 0 – 9999 (Display Units) 2400
31 S1 Reference RPM 0 – 9999 (RPM) 2400
32 S1 Pulses per Revolution 1 – 2048 (PPR) 1
33 S1 Deadband (Follower Mode Only) 0 – 1000 (Seconds) 0
User