28
Parameter Configuration:
Parameter Value Notes
10 3 Follower Mode Setting
13 3 Decimal point position set to XXX.X on display
20 900 Display minimum is 90.0% of master rate
21 1100 Display maximum is 110.0% of master rate
32 5 Pulses per revolution of shaft encoder or pickup is 5 PPR
37 10 Pulses per revolution of shaft encoder or pickup is 10 PPR
40 7 UIN1 configured as jog command when low
41 350 UIN1 jog setpoint is 350 RPM